3-7. Electrical Service Guide
Migmatic Model | 221 |
| 253 |
|
|
|
|
| |
Input Voltage | 220/230 | 230 |
| 400 |
|
|
|
|
|
Input Amperes at Rated Output | 26 | 23 |
| 13 |
|
|
|
|
|
Max Recommended Standard Fuse or Circuit Breaker Rating in Amperes | 26 | 23 |
| 13 |
|
|
|
|
|
** Input Conductor Size in mm2 | 4 | 4 |
| 4 |
** Grounding Conductor Size in mm2 | 4 | 4 |
| 4 |
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters. Consult national and local regulations.
A. 1-Phase
|
|
| Y Installation must meet all National | ||
| 1 |
|
| and Local Codes − have only quali- | |
|
|
| fied persons make this installation. | ||
|
|
| Y Disconnect and lockout/tagout in- | ||
| 5 |
|
| put power before connecting input | |
| =GND/PE |
| conductors from unit. | ||
|
|
| |||
|
| Earth Ground | Y Always connect green or green/ | ||
|
|
| |||
|
| 7 |
| yellow | conductor to supply |
|
|
|
| grounding terminal first, and never | |
|
|
|
| to a line | terminal. |
|
|
| 1 Black And White Input Conductor | ||
18 in (457 mm) | 4 |
|
| (L1 And L2) | |
for airflow |
|
| 2 | Green Or Green/Yellow Grounding | |
| 6 |
| Conductor | ||
| 3 | Input Power Cord. | |||
|
|
| |||
| L1 |
| 4 Disconnect Device (switch shown in | ||
| 1 |
| the OFF position) | ||
| L2 | 5 | Disconnect Device Grounding | ||
|
| ||||
| 2 |
|
| Terminal |
|
|
|
| 6 Disconnect Device Line Terminals | ||
|
|
| Connect green or green/yellow grounding | ||
|
|
| conductor to disconnect device grounding | ||
| 3 |
| terminal first. |
| |
|
| Connect input conductors L1 and L2 to | |||
|
|
| |||
|
|
| disconnect device line terminals. | ||
|
|
| 7 | ||
|
|
| Select type and size of | ||
|
|
| protection using Section | ||
|
|
| connect switch shown). | ||
|
|
| Close and secure door on disconnect | ||
|
|
| device. Remove lockout/tagout device, | ||
|
|
| and place switch in the On position. |