Miller Electric S-74DX manual Adjust Control, Sequence Push Button

Page 25

6-8. Adjust Control

1

Adjust

1 Adjust Control

The Adjust control is used to change various sequence parame- ters, and to select various se- quences. Refer to the section for the function in question for informa- tion related to using the Adjust con- trol.

1

Non-CE Models

CE Models

6-9. Sequence Push Button

3

Start

3

Crater

 

 

 

 

Pre/Postflow

 

 

 

2

 

 

1

 

Sequence

 

Non-CE Models

 

1

Sequence Push Button

 

2 Sequence Push Button LED

 

3

Welding Sequence LEDs

 

Start

Weld

Crater

2

Time

Time

Time

 

 

1

Preflow

 

Postflow

Time

 

 

 

 

 

Time

 

 

 

 

Welding Sequence Diagram

CE Models

 

 

 

.For more information on Setting Sequence Parameters see Section 7-1.

The Sequence push button allows the selection of welding sequences. Five weld- ing sequences are available. The default sequence is the Weld sequence. The Weld sequence is active on power up. Three welding sequence LEDs are located above the Sequence push button: Start, Crater, and Preflow/Postflow. The applicable LED illuminates to indicate which welding se- quence is active.

The LED illuminates to indicate that a weld- ing sequence display mode other than Weld is activate. Welding sequences other than Weld must be set prior to initiating the arc. When the unit enters a welding state, all se- quence display modes are terminated and

the weld display mode is activated.

If zero time is programmed for a timed se- quence except for Weld, that sequence will be skipped.

In the weld sequence display mode the Se- quence push button LED is Off. When the Sequence push button is pressed, the Se- quence push button flashes and the Start LEDs flash. In this condition, the unit is in the Start sequence display mode, and Start se- quence parameters are shown in the dis- plays.

When the Sequence push button is pressed a second time, the Crater sequence LED flashes. The Sequence push button LED re- mains flashing. In this condition, the unit is in the Crater sequence display mode, and Crater sequence parameters are shown in the displays.

When the Sequence push button is pressed a third time, the Preflow/Postflow sequence LED flashes. The Sequence push button LED remains flashing. In the Preflow display mode the upper display shows the preflow time and the lower display indicates the ab- breviation PRE, to inform the operator that preflow time is displayed. If the upper dis- play push button is pressed, the Adjust con- trol can be used to adjust preflow.

If the lower display push button is pressed, the Adjust control can be used to select between preflow PRE and postflow POST. When POST is selected, the upper display can be used to specify postflow time.

When the Sequence push button is pressed a fourth time, the unit returns to the welding sequence display mode.

OM-1500-9 Page 21

Image 25
Contents Processes OM-1500-9 207 749KDescription File MIG GmawFrom Miller to You Table of Contents Standards DirectivesMarks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers LES Fumées ET LES GAZ peuvent être dangereux UNE Décharge Électrique peut entraîner la mortIndique un message de sécurité particulier Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécurité− Definitions + +Rating Label For CE Products Symbols And DefinitionsSpecifications − Installation− Introduction Site SelectionRear Panel Connections And Rotating Drive Assembly Motor Speed Wire Type Wire Size Feed Speed Capability Wire Type, Size, And Feed Speed Capability TablePin Plug Information Gun Recommendation TableExtending from outlet wire guide as Installing And Threading Welding WirePosition Settings And Results For DIP Switch S1 Setting Internal DIP SwitchesDefining Motor Speed S1-7 Power Source Selection Menu − Operation Power SwitchOperational Terms Program Push ButtonFront Panel Controls Wire SpeedTime sec Volts Upper DisplayLower Display Setup Push ButtonSequence Push Button Adjust ControlAuxiliary Menus Power Source Selection Menu Reset To Factory SettingsTrigger Hold Setup Wire Feed Speed UnitsSoftware Revision Level Jog/PurgeCode Display HoldSequence Parameters In a Program − Setting Sequence Parameters− Maintenance − Setting Dual Schedule ParametersOptional Dual Schedule Switch Diagrams Routine MaintenanceLED3-Related Error Indications DiagnosticsCircuit Diagram − Electrical DiagramOM-1500-9 Main Assembly − Parts ListPart Description Quantity Control Box 207 Drive Assembly, Wire PLG5 Roll Kit Drive Roll Fraction Metric Drive Roll And Wire Guide KitsRoll Kit Drive Roll Work like a Pro Page Support ServiceMiller Electric Mfg. Co Owner’s Record