Miller Electric R-115 manual Drive Roll & Wire Guide Kits

Page 31

Table 7-1. Drive Roll & Wire Guide Kits

NOTE

Base selection of drive rolls upon the following recommended usages:

1.V-Grooved rolls for hard wire.

2.U-Grooved rolls for soft and soft shelled cored wires.

3.U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).

4.V-Knurled rolls for hard shelled cored wires.

5.Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination with U-Grooved).

Wire Diameter

 

Kit No.

Drive Roll

Wire Guide

Fraction

Decimal

Metric

Part No.

Type

Inlet

Intermediate

 

 

 

 

 

 

 

 

 

.023/.025 in

.023/.025 in

0.6 mm

087 132

087 130

V-Grooved

056 192

056 206

 

 

 

 

 

 

 

 

.030 in

.030 in

0.8 mm

046 780

053 695

V-Grooved

056 192

056 206

.035 in

.035 in

0.9 mm

046 781

053 700

V-Grooved

056 192

056 206

.040 in

.040 in

1.0 mm

191 917

053 696

V-Grooved

056 192

056 206

.045 in

.045 in

1.2 mm

046 782

053 697

V-Grooved

056 193

056 207

 

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

046 783

053 698

V-Grooved

056 193

056 207

1/16 in

.062 in

1.6 mm

046 784

053 699

V-Grooved

056 195

056 209

 

 

 

 

 

 

 

 

.035 in

.035 in

0.9 mm

044 750

072 000

U-Grooved

056 192

056 206

 

 

 

 

 

 

 

 

.045 in

.045 in

1.2 mm

046 785

053 701

U-Grooved

056 193

056 207

 

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

046 786

053 702

U-Grooved

056 193

056 207

 

 

 

 

 

 

 

 

1/16 in

.062 in

1.6 mm

046 787

053 706

U-Grooved

056 195

056 209

5/64 in

.079 in

2.0 mm

046 788

053 704

U-Grooved

056 195

056 209

 

 

 

 

 

 

 

 

3/32 in

.094 in

2.4 mm

046 789

053 703

U-Grooved

056 196

056 210

.035 in

.035 in

0.9 mm

046 792

132 958

V-Knurled

056 192

056 206

.045 in

.045 in

1.2 mm

046 793

132 957

V-Knurled

056 193

056 207

.052 in

.052 in

1.3 mm

046 794

132 956

V-Knurled

056 193

056 207

 

 

 

 

 

 

 

 

1/16 in

.062 in

1.6 mm

046 795

132 955

V-Knurled

056 195

056 209

 

 

 

 

 

 

 

 

.068-.072 in

.068-.072 in

1.8 mm

089 985

132 959

V-Knurled

056 195

056 209

5/64 in

.079 in

2.0 mm

046 796

132 960

V-Knurled

056 195

056 209

 

 

 

 

 

 

 

 

3/32 in

.094 in

2.4 mm

046 797

132 961

V-Knurled

056 196

056 210

.045 in

.045 in

1.2 mm

083 319

083 489

U-Cogged

056 193

056 207

.052 in

.052 in

1.3 mm

083 320

083 490

U-Cogged

056 193

056 207

1/16 in

.062 in

1.6 mm

046 800

053 708

U-Cogged

056 195

056 209

5/64 in

.079 in

2.0 mm

046 801

053 710

U-Cogged

056 195

056 209

 

 

 

 

 

 

 

 

3/32 in

.094 in

2.4 mm

046 802

053 709

U-Cogged

056 196

056 210

Ref. S-0025-D

OM-193 471 Page 27

Image 31
Contents File MIG Gmaw OM-193 471PProcesses DescriptionFrom Miller to You Table of Contents Page Electric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal can injure eyesCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers Signifie Note n’est pas relatif à la sécurité UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux Indique un message de sécurité particulierDES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer unIncendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Organes Mobiles peuvent provoquer des blessures Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peut SUREn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéPower SpecificationsWelding Power WireShielding gas pressure not to exceed 100 PSI 689 kPa Equipment Connection DiagramsRear Panel Connections And Power Switch Location Gun Recommendation TableConnecting Welding Gun And Weld Cable Installing Wire Guide And Drive Roll Wood Installing And Threading Welding WireMove lead 38 at terminal block For welding power sources reGround lead must be wrapped Quiring dry contact closureAccording to -9before Make ground lead connectionsTo Terminal E Lead For Welding power sourcesWhite Tools Needed RedBlack White Lead Motor Start/Burnback Control Optional Side Panel Controls Front Panel ControlsMonths Routine MaintenanceOverload Protection Trouble Remedy Troubleshooting− Electrical Diagram − Parts List PLG4 Hardware is common Drive Assembly, Wire -2 ItemDrive Roll & Wire Guide Kits OM-193 471 OM-193 471 OM-193 471 Support ServiceMiller Electric Mfg. Co Owner’s Record