3-8. Installing And Threading Welding Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

 

 

 

A

B

C

Tighten

WOOD

1Retaining Ring

2Hub Tension Adjustment Nut

If necessary, move hub on support for use of different size wire spool.

Remove retaining ring, and install spool so hub pin fits spool hole. Reinstall retaining ring.

Adjust tension nut so wire is taut when wire feed stops.

3Pressure Assembly Adjustment Knob

Lay gun cable out straight.

AOpen pressure assemblies, hold wire tightly, and cut off end. Push wire through guides into gun.

BClose and tighten pressure assemblies. Press JOG button until the wire comes out of the gun.

CTo adjust drive roll pressure,

press gun trigger to feed wire against wood surface. Tighten knob so wire does not slip.

Cut off wire. Close door.

Tools Needed: 15/16 in

Ref. 802 308 / S-0627-A

OM-193 471 Page 13

Image 17
Contents Processes OM-193 471PDescription File MIG GmawFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information LES Fumées ET LES GAZ peuvent être dangereux UNE Décharge Électrique peut entraîner la mortIndique un message de sécurité particulier Signifie Note n’est pas relatif à la sécuritéIncendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéWelding Power SpecificationsWire PowerRear Panel Connections And Power Switch Location Equipment Connection DiagramsGun Recommendation Table Shielding gas pressure not to exceed 100 PSI 689 kPaConnecting Welding Gun And Weld Cable Installing Wire Guide And Drive Roll Wood Installing And Threading Welding WireGround lead must be wrapped For welding power sources reQuiring dry contact closure Move lead 38 at terminal blockAccording to -9before Make ground lead connectionsTo Terminal E Lead For Welding power sourcesBlack Tools Needed RedWhite White Lead Motor Start/Burnback Control Optional Side Panel Controls Front Panel ControlsOverload Protection Routine MaintenanceMonths Trouble Remedy Troubleshooting− Electrical Diagram − Parts List PLG4 Hardware is common Drive Assembly, Wire -2 ItemDrive Roll & Wire Guide Kits OM-193 471 OM-193 471 OM-193 471 Support ServiceMiller Electric Mfg. Co Owner’s Record