Miller Electric R-115 manual Make ground lead connections, According to -9before

Page 19

3-11. Connection For Hobart Welding Power Sources With 19-Socket Receptacle

 

 

. Make ground lead connections

 

 

according to Section 3-9before

 

 

following this procedure.

 

 

3

 

C

D E

A

B

 

1

 

L M A

 

K U N B

 

 

J T V P C

 

 

H S R D

 

 

G F E

 

 

2

Tools Needed:

 

 

 

1/4 in

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:Dry Contact Closure w/Respect To Terminal E Lead

E:115 VAC/Contact Closure Lead

.For welding power sources

requiring dry contact closure, move lead 38 at terminal block to terminal D.

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Ref. 802 310 / Ref. 193 749

3-12. Connection For L-TEC Welding Power Sources With 19-Socket Receptacle

A

1

B C

. Make ground lead connections according to Section 3-9before following this procedure.

3

D E

L M A

K U N B

J T V P C

H S R D

G F E

2

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:No Connection

E:115 VAC/Contact Closure Lead

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Tools Needed:

1/4 in

Ref. 802 310 / Ref. 193 749

OM-193 471 Page 15

Image 19
Contents File MIG Gmaw OM-193 471PProcesses DescriptionFrom Miller to You Table of Contents Page Electric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal can injure eyesCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers Signifie Note n’est pas relatif à la sécurité UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux Indique un message de sécurité particulierDES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer unIncendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Organes Mobiles peuvent provoquer des blessures Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peut SUREn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéPower SpecificationsWelding Power WireShielding gas pressure not to exceed 100 PSI 689 kPa Equipment Connection DiagramsRear Panel Connections And Power Switch Location Gun Recommendation TableConnecting Welding Gun And Weld Cable Installing Wire Guide And Drive Roll Wood Installing And Threading Welding WireMove lead 38 at terminal block For welding power sources reGround lead must be wrapped Quiring dry contact closureAccording to -9before Make ground lead connectionsTo Terminal E Lead For Welding power sourcesWhite Tools Needed RedBlack White Lead Motor Start/Burnback Control Optional Side Panel Controls Front Panel ControlsMonths Routine MaintenanceOverload Protection Trouble Remedy Troubleshooting− Electrical Diagram − Parts List PLG4 Hardware is common Drive Assembly, Wire -2 ItemDrive Roll & Wire Guide Kits OM-193 471 OM-193 471 OM-193 471 Support ServiceMiller Electric Mfg. Co Owner’s Record