Miller Electric UWF-SC12RC Setting Digital Meter Board PC4 DIP Switches, Wire Feed Speed Display

Page 17

4-2. Setting Digital Meter Board PC4 DIP Switches

1

2

3Meter DIP switches are factory set to display wirefeed speed and voltage using 14 pin feedback. Meter hold feature is factory set to off position.

Wire Feed Speed Display

Inches Per Minute

Meters Per Minute

 

S1

 

S1

S2

S2

S2

S2

14 Pin

Voltage/Current

14 Pin

Voltage/Current

Voltage

Sense Kit

Voltage

Sense Kit

Feedback

(195194)

Feedback

(195194)

1Front Meter Panel

2S1 DIP Switch

3S2 DIP Switch

If the DIP switches are set to a Meter Hold (ON) position, the meter value will hold 5 seconds after gun is trig- gered. The meter value will continue to hold for 8 seconds after trigger is released or until gun is re-triggered.

.When using power sources without 14 pin voltage/current feedback − optional remote voltage/current kit 195194 is required.

Indicates this DIP switch setting has no effect on this function.

 

Meter Hold

(ON)

(OFF)

S1

S1

Amps Display

S2

S2

14Pin

Current Feedback

Voltage/Current Sense Kit (195194)

803 141/ Ref. 803 124

OM-215 092 Page 13

Image 17
Contents Processes OM-215Description 210 177APage Table of Contents Standards DirectivesMarks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information − Definitions Symbols And Definitions − InstallationSpecifications Manufacturer’s Rating Label For CE ProductsPin Pin Information Equipment Connection DiagramPin Plug Information Consumable Parts and Spares for the T-400 MP Torch Gun Recommendation TableInstalling Wire Guide And Drive Rolls Installing And Aligning Wire Guide And Drive RollsAligning Wire Guide And Drive Rolls Cleaning Drive RollsConnecting Shielding Gas Connecting Welding GunInstalling And Threading Welding Wire Connecting Weld CableInstalling Wire And Adjusting Hub Tension Threading Welding WireControls − OperationWire Feed Speed Display Setting Digital Meter Board PC4 DIP SwitchesMeter Hold Amps DisplayEngine on welding generator − Maintenance & TroubleshootingOverload Protection And Thermostat Protection Trouble Remedy TroubleshootingOM-215 092 Circuit Diagram For Wire Feeder − Electrical DiagramsComplete Assembly − Parts ListDia Part Description Mkgs Quantity ME081 193-603340 193-603118193-603373 193-603142Page Page Unitor ASA