3-2. 14-Pin Plug Information
|
|
| Pin* | Pin Information |
|
|
| A | 24 volts ac with respect to socket G. |
J |
| A | B | Contact closure to A completes 24 volts ac contactor control circuit. |
K |
|
| ||
I | B | G | Circuit common for 24 volts AC circuit. | |
H | N | L C | C | +10 volts dc input from power source to wire feeder with respect to socket D. |
G | M | D | D | Remote control circuit common. |
F | E |
| ||
|
|
| ||
|
|
| E | 0 to +10 volts dc output signal from wire feeder to power source with respect to socket D. |
|
|
| H | Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts. |
|
|
| F | Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes. |
*The remaining pins are not used.
3-3. Equipment Connection Diagram
1
2
3
5
4
6
11
10
9
8
1Constant Voltage (CV) Welding Power Source Supplying 24 VAC To Feeder
Use optional
2Negative (−) Weld Cable
3Positive (+) Weld Cable
4Workpiece
5Interconnecting Cord (Customer Supplied)
6
7Wire Feeder
8Gun
9Gun Trigger Receptacle
10Gas Hose
11Gas Cylinder
.Shielding gas pressure not to exceed 90 psi (620 kPa).
7
804