SECTION 3 − INSTALLATION
3-1. Specifications
|
|
| Amperes Input at Rated Load Output, |
|
| ||||
| Voltage Range |
|
| 60 Hz, |
|
|
| ||
|
|
|
|
|
|
|
|
| |
Rated Welding Output | DC | Max OCV DC | 230 V |
| 460 V |
| 575 V | KVA | KW |
|
|
|
|
|
|
|
|
|
|
375 A @ 35 Volts DC, | 10 − 45 | 45 | 69 |
| 34.5 |
| 27.5 | 27.5 | 17.5 |
100% Duty Cycle | 4* |
| 2* |
| 1.6* | 1.61* | 0.46* | ||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
*While idling
3-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.
If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.
Y Exceeding duty cycle can damage unit and void warranty.
100% Duty Cycle
Continuous Welding
Overheating | V |
|
0 |
| |
| 15 |
|
| OR |
|
Minutes | Reduce Duty Cycle | 209 810 |
|