5-4. Troubleshooting Table
|
|
|
|
|
|
|
|
|
|
| Trouble |
| Remedy | |
|
| |||
No weld output; unit completely | Place line disconnect switch in On position (see Section | |||
inoperative. |
|
| ||
|
|
|
| |
|
|
| Check fuse F1, and replace if necessary (see Section | |
|
|
|
| |
|
|
| Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section | |
|
|
|
| |
|
|
| Check for proper input power connections (see Section | |
|
|
|
| |
|
|
| Check for proper jumper link position (see Section | |
|
| |||
No weld output; Power switch pilot light | Check, repair, or replace feeder (see wire feeder Owner’s Manual). | |||
on; fan on. |
|
| ||
|
|
|
| |
|
|
| Unit overheated. Allow unit to cool with fan On (see Section | |
|
|
|
| |
|
|
| Have Factory Authorized Service Agent check control board PC1. | |
|
| |||
Unit provides only maximum or mini- | Have Factory Authorized Service Agent check control board PC1. | |||
mum weld output. |
|
| ||
|
| |||
Erratic or improper weld output. | Use proper size and type of weld cable (see Section | |||
|
|
|
| |
|
|
| Clean and tighten all weld connections. | |
|
|
|
| |
|
|
| Check wire feeder installation according to Owner’s Manual. | |
|
|
|
| |
|
|
| Have Factory Authorized Service Agent check control board PC1 and/or SCR in main rectifier. | |
|
| |||
No 115 volts ac output at duplex | Reset supplementary protector CB1 (see Section | |||
receptacle or Remote 14 receptacle. |
|
| ||
|
| |||
No 24 volts ac output at Remote 14 re- | Reset supplementary protector CB2 (see Section | |||
ceptacle. |
|
| ||
|
| |||
Fan not operating. | Check for and remove anything blocking fan movement. | |||
|
|
|
| |
|
|
| Have Factory Authorized Service Agent check fan motor. | |
|
|
|
|
|