Miller Electric Delta-Fab manual Electrical Service Guide, Placing Jumper Links, Input Voltage

Page 19

3-12. Electrical Service Guide

Input Voltage

230

460

575

 

 

 

 

Input Amperes At Rated Output

69

34.5

27.5

 

 

 

 

Max Recommended Standard Fuse Rating In Amperes 1

 

 

 

Time-Delay 2

80

40

30

Normal Operating 3

100

50

40

 

 

 

 

Min Input Conductor Size In AWG 4

4

8

10

 

 

 

 

Max Recommended Input Conductor Length In Feet (Meters)

237

422

444

(72)

(129)

(135)

 

 

 

 

 

Min Grounding Conductor Size In AWG 4

8

10

10

 

 

 

 

Reference: 2005 National Electrical Code (NEC)

1Consult factory for circuit breaker applications.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

4Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

3-13. Placing Jumper Links

Y Disconnect and lockout/tag- out input power before installing or moving jumper links.

Check input voltage available at site.

1 Jumper Link Label

Check label − only one is on unit.

2 Jumper Links

Move jumper links to match input voltage.

Close and secure access door, or go on to Section 3-14.

1

230 VOLTS

460 VOLTS

575 VOLTS

 

 

Ref. S-174 973-B

2

Tools Needed:

 

3/8 in

 

3/8 in

Do not overtighten

 

jumper link nuts.

 

Ref. 800 103-A

OM-2241 Page 15

Image 19
Contents File MIG Gmaw OM-2241209 815HProcesses DescriptionFrom Miller to You Table of Contents Page Electric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal can injure eyesCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers LES Fumées ET LES GAZ peuvent être dangereux UNE Décharge Électrique peut entraîner la mortIndique un message de sécurité particulier DES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer unIncendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Organes Mobiles peuvent provoquer des blessures Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peut SUREn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéOverheating SpecificationsDuty Cycle And Overheating 230Volt-Ampere Curves Movement Be careful when placing or moving unit over uneven surfacesSelecting a Location TippingVAC Receptacle And Supplementary Protectors Dimensions And WeightsDimensions WeightWeld Output Terminals And Selecting Cable Sizes Connecting Weld Output CablesDuty Cycle Information Turn off power before con- necting to receptacleRemote 14 Receptacle RC8 Remote 14 Receptacle RC8 InformationInput Amperes At Rated Output Electrical Service GuidePlacing Jumper Links Input VoltageWelding Power Source Input Power Connections Connecting Input PowerDisconnect Device Input Power Con- nections Disconnect input power before maintaining Months Routine MaintenanceControls Fuse F1 Disconnect input power be- fore opening rear access doorShort Circuit Shutdown Trouble Remedy Troubleshooting Table− Electrical Diagram OM-2241 − Parts List 1Main Assembly Panel, Front w/Components 175 Rectifier, Si Diode SR1Panel, Rear w/Components Support ServiceMiller Electric Mfg. Co Owner’s Record