Simer Pumps 2325, 2360, 2385 owner manual Read and Follow Safety Instructions, General Safety

Page 2

Safety

2

READ AND FOLLOW

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.

warns about hazards that will cause serious personal injury, death or major property damage if ignored.

warns about hazards that can cause serious personal injury, death or major property damage if ignored.

warns about hazards that will or can cause minor personal injury or property damage if ignored.

The label NOTICE indicates special instructions which are important but not related to hazards.

GENERAL SAFETY

Carefully read and follow all safety instructions in this manual and on pump.

Keep safety labels in good condition.

Replace missing or damaged safety labels.

To avoid serious injury and/or property damage, read and follow these rules and instructions carefully.

1.Pump is designed for use with clean, cold, fresh water. Pump water only with this pump.

2.Do not lift pump by power cord at any time. Attempting to lift or support the pump by the power cord can damage the cord and cord connections, and will void warranty. Always lift the pump by the lifting handle.

3.Meet National Electrical Code, Canadian Electrical Code, and local codes for all wiring.

4.Installation must comply with all local codes per- taining to utility pumps.

5.Know the pump application, limitations, and poten- tial hazards.

6.Disconnect the power before servicing.

7.Release all pressure within the system before servic- ing any component.

8.Drain all water from the system before servicing.

9.Secure the discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.

10.Check hoses for weak or worn condition before each use, making certain that all connections are secure.

11.Periodically inspect the pump and system compo- nents. Keep the pump inlet free of debris and foreign objects. Perform routine maintenance as required.

12.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep work area clean, uncluttered and properly lighted – replace all unused tools and equipment.

c.Keep visitors at a safe distance from work area.

d.Make workshop child-proof – with padlocks, mas- ter switches, and by removing starter keys.

13.This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conduc- tor cord and 3-prong, grounding-type plug.

Hazardous voltage. Can shock, burn or cause death. To reduce risk of electric shock, pull plug before servicing. This pump has not been investigated for use in swimming pool areas. Pump is supplied with a grounding conductor and grounding-type attachment plug. Be sure it is connected only to an individual branch circuit with a properly grounded grounding-type receptacle. Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.

14.Make certain power source conforms to requirements of your equipment.

15.Protect the electrical cord from sharp objects, hot sur- faces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.

16.Do not touch an operating motor. Modern motors are designed to operate at high temperatures.

17.Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water.

18.Do not use in water where fish are present.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 2
Contents Mod , 2360 CallGeneral Safety SafetyRead and Follow Safety Instructions Table of Contents General Information Operation Installation / OperationInstallation Maintenance MaintenanceTroubleshooting Symptom Possible Causes Corrective ActionSécurité Générale SécuritéLire Toutes CES Instructions ET LES Suivre Table des matières Garantie limitée SimerCaractéristiques Électriques Renseignements générauxSpécifications Raccords DE RefoulementInstallation / Fonctionnement FonctionnementEntretien Diagnostic des pannesEntretien Symptômes Causes Possibles RemèdesSeguridad General SeguridadLEA Y Siga LAS Instrucciones DE Seguridad Indice de Contenido Garantía limitada de SimerInformación general Operación Instalación / OperaciónInstalación Mantenimiento Solución de ProblemasMantenimiento Síntoma Posibles Causas Acción Correctiva

2325, 2360, 2385 specifications

Simer Pumps has established itself as a reliable provider of high-quality pump solutions that cater to various industries. Among their impressive lineup, the Simer Pumps 2385, 2360, and 2325 models stand out due to their advanced technologies and robust characteristics, making them suitable for numerous applications.

The Simer Pumps 2385 is designed for high-efficiency performance and durability. This model is particularly known for its ability to handle a wide range of fluids, including corrosive liquids. Its construction features high-grade materials, providing excellent resistance to wear and tear. The 2385 is equipped with a powerful motor that allows it to deliver a high flow rate while maintaining energy efficiency. Additionally, it incorporates a user-friendly interface, making it easy for operators to monitor and control operations.

The Simer 2360 model is recognized for its versatility and reliability. It comes with an innovative impeller design that enhances performance by maximizing fluid movement while minimizing energy consumption. This model often features a self-priming design, allowing it to operate effectively even in applications where the pump is not fully submerged. Its compact size makes it perfect for installations in tight spaces, and the improved sealing technology ensures minimal maintenance is required over its operational lifetime.

The Simer Pumps 2325 is tailored for applications requiring a consistent and steady flow. This model is characterized by its low noise operation and high thermal resistance, making it ideal for environments where sound and heat must be minimized. The 2325 utilizes advanced motor technology, which enhances its overall efficiency and reduces energy costs. Typically, it features a modular design that simplifies repairs and part replacements, ensuring minimal downtime for users.

All three Simer Pumps models are designed with a focus on user convenience and long-term performance. They incorporate technological advancements that prioritize energy efficiency, making them environmentally friendly options in industrial settings. The combination of durability, efficiency, and ease of maintenance makes the Simer Pumps 2385, 2360, and 2325 models a wise investment for businesses looking to enhance their fluid transfer systems. Whether for industrial, commercial, or residential use, these pumps exemplify Simer’s commitment to quality and innovation in pumping technology.