3-3. Typical Equipment Location

4

3

2

1

5

6

 

 

 

 

 

7

1

Welding Power Source

4

Weld Control

6

Wire Drive Assembly

2

Gas Cylinder

5

Spool Support

7

Automatic Welding Gun

3

Side Beam

 

 

 

ST-131 138-A

3-4. Installing Drive Rolls

4

3

2

1

1Pressure Assembly Door

2Drive Roll

3Ejector Button

4Drive Roll Carrier

Installation

Open pressure assembly door.

Align drive roll slots with three lobes on drive roll carrier.

Insert drive roll onto carrier. Drive roll will snap into place.

Removal

.Remove PD wire guide before removing lower drive rolls.

Lift up drive roll swing arm and press ejector button in middle of drive roll carrier.

.If ejector button does not re-

turn to normal position (out), install a drive roll and ejector button will pop out.

804 187-A

OM-227 674 Page 10

Image 14
Contents Description OM-227 674BProcesses File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux DES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer unIncendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures graves’EMPLOI Excessif peut SUR Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaquesAdapter Bracket SpecificationsOverall Dimensions And Mounting Hole Layout Typical Equipment Location Installing Drive RollsInstallation RemovalInstalling PD Continuous Wire Guides Installing PD continuous wire guides with PD drive rollsInstalling Non-PD Old Style Wire Guides Installing wire guides with non- PD old-style drive rollsInstalling gun without Accu- Mate connection Installing Welding GunInstalling gun with Accu-Mate connection Mounting Motor And Connecting Gas Hose And Weld Cable Drive motor must be isolated from weld potentialPlug Connections Threading Welding Wire And Adjusting Pressure Drive Setting PowerjogDisconnect power before maintaining Routine MaintenanceBrush Inspection And Replacement Troubleshooting Circuit Diagram For AA40GBU/Gas Box Left Hand− Parts List Drive Assembly, Wire Drive Assembly, Wire -1Item 219Guides for Old Style Drive Service SupportOwner’s Record Miller Electric Mfg. Co