3-7. Installing Welding Gun

4

3

 

Installing gun with

Installing gun without

 

Accu-Mate connection

 

Accu-Mate connection

 

 

 

2

2

1

 

 

1

 

 

1Power Clamp Knob

2Gun Locking Tab

3Power Pin Groove

4Gun Connection End

Installing gun with Accu-Mate connection

Loosen power clamp knob to allow power pin of gun to clear the gun locking tab.

When installing gun, the liner should extend into the PD continu- ous guide (or exit guide if used) as far as possible without interfering with the guide.

Align the groove in the power pin of the gun with the gun locking tab.

Secure gun by tightening power clamp knob.

Installing gun without Accu- Mate connection

When using a gun without the groove in the power pin, loosen power clamp knob and rotate gun locking tab 180 degrees. This pre- vents the locking tab from extend- ing into the power pin gun connec- tion.

When installing gun, the liner should extend into the PD continu- ous guide (or exit guide if used) as far as possible without interfering with the guide.

Secure gun by tightening power clamp knob.

804 189-A

OM-227 674 Page 13

Image 17
Contents Processes OM-227 674BDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéAdapter Bracket SpecificationsOverall Dimensions And Mounting Hole Layout Installation Installing Drive RollsTypical Equipment Location RemovalInstalling PD continuous wire guides with PD drive rolls Installing PD Continuous Wire GuidesInstalling wire guides with non- PD old-style drive rolls Installing Non-PD Old Style Wire GuidesInstalling gun without Accu- Mate connection Installing Welding GunInstalling gun with Accu-Mate connection Drive motor must be isolated from weld potential Mounting Motor And Connecting Gas Hose And Weld CablePlug Connections Powerjog Threading Welding Wire And Adjusting Pressure Drive SettingDisconnect power before maintaining Routine MaintenanceBrush Inspection And Replacement Circuit Diagram For AA40GBU/Gas Box Left Hand Troubleshooting− Parts List Drive Assembly, Wire 219 Drive Assembly, Wire -1ItemGuides for Old Style Drive Support ServiceMiller Electric Mfg. Co Owner’s Record