4-2. Optional Side Panel Controls
4
1
2
3
1 Preflow Control
Control sets time gas flows before welding wire is energized. Time range is 0 to 5 seconds.
2 Postflow Control
Control sets time gas flows after completion of burnback. Time range is 0 to 5 seconds.
3 Spot Time Control
Factory set for 0.25 to 5 seconds of spot time. Rotating knob fully counterclockwise selects an untimed continuous weld.
4
Use control to set wire feed speed before arc initiation.
Close side door.
Ref. 802
SECTION 5 − MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
Y Disconnect power before maintaining.
3 Months
Replace
Unreadable
Labels
Repair Or
Replace
Cracked
Weld Cable
Clean And
Tighten
Weld
Terminals
Replace
Cracked
Parts
Gun Cable | Gas Hose |
6 Months
Clean
Drive
Rolls
Blow Out Or Vacuum
Inside,
ORDuring Heavy Service,
Clean Monthly