Miller Electric Regency 250 manual Volt-Ampere Curves, Selecting a Location

Page 14

2-3. Volt-Ampere Curves

Volt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown.

va_curve1 4/95 – 049 424-E

2-4. Selecting A Location

Movement

1

Location And Airflow

Tools Needed:

3

 

3/8 in

 

1 Lifting Forks

Use lifting forks to move unit.

Extend forks beyond opposite side of unit.

2 Rating Label

Use rating label to determine input power needs.

3 Line Disconnect Device

Locate unit near correct input pow- er supply.

YSpecial installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC Section 20.

2

18in

(460 mm)

18in

(460 mm)

800 402 / Ref. 121 471-H

OM-293 Page 10

Image 14
Contents Description OM-293Processes From Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersUN Choc É Lectrique peut tuer Signification des symbolesConsignes DE Securite Lire Avant Utilisation LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux ’EMPLOI Excessif peut Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques Duty Cycle And Overheating InstallationSpecifications While idlingMovement Location And Airflow Volt-Ampere CurvesSelecting a Location Dimensions And Weights Weld Output Terminals And Selecting Cable SizesSocket Electrical Service GuideRemote 14 Receptacle Information Input VoltagePlacing Jumper Links And Connecting Input Power Operation ControlsTroubleshooting Maintenance & TroubleshootingRoutine Maintenance Disconnect power before maintainingElectrical Diagram Circuit Diagram For Welding Power SourceParts List Main AssemblyPanel, Front w/Components Panel, Front w/Components -1 Item Panel, Rear w/Components -1 Item Page Page Service SupportOwner’s Record Miller Electric Mfg. Co