SECTION 3 – OPERATION
3-1. Controls
1
2
3
4
5
6
1 Voltage Range Switch
Use switch to select voltage range.
2 Voltage Adjustment Switch
Use switch to adjust voltage within range se- lected by Voltage Range switch. Each posi- tion of the switch is a change of 2 volts.
YDo not change position of Voltage Range switch or Voltage Adjustment switch while welding. Arcing can da- mage contacts, causing connections to fail.
3Power Switch
4Pilot Light
Ref. 121
5 Circuit Breaker CB2
If CB2 opens, the 24 volts ac output to the Re- mote 14 receptacle stops.
6 Circuit Breaker CB1
If CB1 opens, the 115 volts ac output to the Remote 14 receptacle stops.