Miller Electric Regency 250 manual Placing Jumper Links And Connecting Input Power

Page 17

2-9. Placing Jumper Links And Connecting Input Power

 

1

 

 

200V

230V

460V

 

 

 

S-153 408-A

2

 

 

 

Check input voltage available at site.

1Jumper Link Label

2Jumper Link

Move jumper links to match input power.

3 Line Disconnect Device

Select type and size of overcurrent protection using Section 2-8. Rat- ings must comply with applicable codes. Install conductors in conduit or equivalent into a deenergized line disconnect device.

Reinstall wrapper.

YSpecial installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC Section 20.

GND/PE

Earth Ground

3

L1

L2

Tools Needed:

3/8 in

S-0279-B / Ref. 121 471-H

OM-293 Page 13

Image 17
Contents Description OM-293Processes From Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards About Pacemakers EMF InformationConsignes DE Securite Lire Avant Utilisation Signification des symbolesUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux LA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques Specifications InstallationDuty Cycle And Overheating While idlingMovement Location And Airflow Volt-Ampere CurvesSelecting a Location Weld Output Terminals And Selecting Cable Sizes Dimensions And WeightsRemote 14 Receptacle Information Electrical Service GuideSocket Input VoltagePlacing Jumper Links And Connecting Input Power Controls OperationRoutine Maintenance Maintenance & TroubleshootingTroubleshooting Disconnect power before maintainingCircuit Diagram For Welding Power Source Electrical DiagramMain Assembly Parts ListPanel, Front w/Components Panel, Front w/Components -1 Item Panel, Rear w/Components -1 Item Page Page Support ServiceMiller Electric Mfg. Co Owner’s Record