Miller Electric Big Blue 251D manual Compressed Air Hazards

Page 7

STEAM AND HOT COOLANT can burn.

DIf possible, check coolant level when engine is cold to avoid scalding.

D Always check coolant level at overflow tank, if pres- ent on unit, instead of radiator (unless told otherwise in maintenance section or engine manual).

DIf the engine is warm, checking is needed, and there is no overflow tank, follow the next two statements.

DWear safety glasses and gloves and put a rag over radiator cap.

DTurn cap slightly and let pressure escape slowly before completely re- moving cap.

ENGINE EXHAUST GASES can kill.

D Use equipment outside in open, well-ventilated ar- eas.

DIf used in a closed area, vent engine exhaust outside and away from any building air intakes.

BATTERY ACID can BURN SKIN and EYES.

DDo not tip battery.

DReplace damaged battery.

DFlush eyes and skin immediately with water.

ENGINE HEAT can cause fire.

DDo not locate unit on, over, or near combustible surfaces or flammables.

DKeep exhaust and exhaust pipes way from flam- mables.

EXHAUST SPARKS can cause fire.

DDo not let engine exhaust sparks cause fire.

DUse approved engine exhaust spark arrestor in re- quired areas — see applicable codes.

1-4. Compressed Air Hazards

BREATHING COMPRESSED AIR can cause serious injury or death.

DDo not use compressed air for breathing.

DUse only for cutting, gouging, and tools.

HOT METAL from air arc cutting and gouging can cause fire or explosion.

DDo not cut or gouge near flammables.

DWatch for fire; keep extinguisher nearby.

COMPRESSED AIR can cause injury.

DWear approved safety goggles.

DDo not direct air stream toward self or others.

HOT PARTS can cause burns and injury.

DDo not touch hot compressor or air system parts.

DLet system cool down before touching or servicing.

TRAPPED AIR PRESSURE AND WHIPPING HOSES can cause injury.

DRelease air pressure from tools and system before servicing, adding or changing attachments, or open- ing compressor oil drain or oil fill cap.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servicing unit.

DStop engine and release air pressure before servicing.

1-5. Additional Symbols For Installation, Operation, And Maintenance

FALLING UNIT can cause injury.

DUse lifting eye to lift unit only, NOT running gear, gas cylinders, trailer, or any other accessories.

DUse equipment of adequate capacity to lift and support unit.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

OVERUSE can cause OVERHEATING.

DAllow cooling period; follow rated duty cycle.

DReduce current or reduce duty cycle before starting to weld again.

DDo not block or filter airflow to unit.

OVERHEATING can damage motors.

DTurn off or unplug equipment before starting or stop- ping engine.

DDo not let low voltage and frequency caused by low engine speed damage electric motors.

DDo not connect 50 or 60 Hertz motors to the 100 Hertz receptacle where applicable.

FLYING SPARKS can cause injury.

DWear a face shield to protect eyes and face.

D Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection.

DSparks can cause fires — keep flammables away.

STATIC (ESD) can damage PC boards.

DPut on grounded wrist strap BEFORE handling boards or parts.

DUse proper static-proof bags and boxes to store, move, or ship PC boards.

TILTING OF TRAILER can cause injury.

DUse tongue jack or blocks to support weight.

DProperly install welding generator onto trailer accord- ing to instructions supplied with trailer.

OM-480 Page 3

Image 7
Contents Engine Driven Welding Generator ProcessesDescription Visit our website at OM-480128 576AC JanuaryFrom Miller to You Table of Contents Options and Accessories Warranty Arc Welding Hazards Symbol UsageEngine Hazards Compressed Air Hazards Radiation can cause interference Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationLES Fumées ET LES GAZ peuvent être dangereux Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation UN Choc Électrique peut tuerLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures graves’AIR Comprimé peut provoquer des blessures ’EXPLOSION DE LA Batterie peutDES Organes Mobiles peuvent provoquer des blessures LA Chaleur DU Moteur peut pro- voquer un incendieInformation sur les champs électromagnétiques Principales normes de sécurité− Definitions Symbols And DefinitionsWeld, Power, And Engine Specifications − SpecificationsDimensions, Weights, And Operating Angles Duty Cycle And Overheating Curve shows typical fuel use under weld or power loadsExceeding duty cycle can damage unit and void warranty Fuel ConsumptionVolt-Ampere Curves AC Generator PowerOptional AC Power Plant Curves Installing Welding Generator − InstallationConnecting The Battery Fuel Do not use gasoline. Gasoline Installing Muffler PipeEngine Prestart Checks Stop engine and let coolConnecting To Weld Output Terminals Installing Ether Cylinder Optional Ether Starting AidPut terminals Selecting Weld Cable Sizes150 ft 200 ft 250 ft 350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 mControls See Section − Operating the Welding GeneratorDo not use Ether if engine is running Description Of Front Panel Controls See SectionRemote A/V Control Stop engine and fix trouble if either light goes onVolt Duplex And Optional Gfci Receptacles − Operating Auxiliary EquipmentX 15 a + 120 V x 10 a = 3.0 kVA/kW OM-480 X 10 a + 120 V x 5 a = 3.0 kVA/kW Volt Duplex Receptacle Optional240 V 15 a AC Receptacle RC1 Circuit Breakers CB1 And CB2Connecting Optional AC Power Plant 240 Volt Twistlock Receptacle Optional − Maintenance and Troubleshooting Maintenance Label Servicing Air Cleaner To replace secondary fuel filter Servicing Fuel And Lubrication SystemsTo change oil and filter To replace primary fuel filterStandard Models Adjusting Engine SpeedModels With Automatic Idle Optional Full Empty Overload Protection Servicing Optional Ether Starting AidWelding Inspecting And Cleaning Optional Spark ArrestorTroubleshooting Stop engine and let cool. Reinstall cleanout plugMaximum see Section Generator PowerCheck connections to ac power plant see Section EngineCircuit Diagram For Welding Generator − Electrical DiagramWetstacking − RUN-IN ProcedureWelding Generator From flammables Do not Perform Run-In Procedure Using Load BankProcedure at less than Stop engine Do not touch hot exhaustDo not perform run-in Run-In Procedure Using Resistance GridBank/grid From flammablesSelecting Equipment − Generator Power GuidelinesGrounding Generator To Truck Or Trailer Frame Amperes x Volts = Watts Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Earth ground if supplyingFarm/Home Equipment Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Industrial Motors Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentKVA/HP x HP x 1000 = Starting Amperage Power Required To Start MotorHow Much Power Can Generator Supply? Single-Phase Induction Motor Starting RequirementsWork like a Pro Typical Connections To Supply Standby PowerCurrent Load Watts Amperes Selecting Extension Cord Use Shortest Cord PossibleOM-480 116 − Parts List125 124 123 122 120 121 1172526 126 Dia Part Description Quantity Mkgs 128 111 Panel, Front w/Components -1ItemPanel, Front w/Components -1Item 111 Cont’d Generator Generator -1Item Includes 114Page Page Your distributor also gives ServiceSupport Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact