4-3. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble | Remedy | |||
|
| ||||
No generator output at platform | Be sure generator control switch is turned on at platform. | ||||
receptacles. |
| ||||
|
|
|
|
|
|
|
|
|
|
| Check and secure electrical connections at platform, generator, and control box. |
|
|
|
|
|
|
|
|
|
|
| Be sure all equipment is turned off when starting unit. |
|
|
|
|
|
|
|
|
|
|
| Reset circuit breaker CB1 (see Section |
|
|
|
|
|
|
|
|
|
|
| Check connections at receptacle RC3. |
|
|
|
|
|
|
|
|
|
|
| Be sure +12 volts dc input voltage is being supplied to control box. |
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and circuit boards PC1 and PC2. |
|
| ||||
Low generator output at platform | Verify generator is running at 3600 rpm. | ||||
receptacles. |
| ||||
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and circuit boards PC1 and PC2. |
|
| ||||
High generator output at platform | Check control settings on welding equipment. | ||||
receptacles. |
| ||||
|
|
|
|
|
|
|
|
|
|
| Verify generator is running at 3600 rpm. |
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and circuit boards PC1 and PC2. |
|
| ||||
Erratic generator output at platform | Check and secure electrical connections at platform, generator, and control box. | ||||
receptacles. |
| ||||
|
|
|
|
|
|
|
|
|
|
| Verify generator is running at 3600 rpm. |
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and circuit boards PC1 and PC2. |
|
|
|
|
|
|