Bad Boy Mowers 02.9812.0001C user manual Group Test, To perform a group test

Page 64

BAD BOY™ SPOT LUMINAIRE USER MANUAL

Group Test

The Group Test menu allows multiple Bad Boy™ luminaires to be run through a configurable test sequence when chained together via DMX512 or Ethernet. (Refer to "Connecting Power and Data" on page 19 for more information about daisy-chaining.)

To perform a group test:

Step

1.

At Group Test screen, select options to run: Pan/Tilt, Intensity, Colors, Gobos, and/or Zoom.

Step

2.

Select test option: concurrently (all selected tests are run at once) or sequentially (tests are

 

 

run one at a time as each one finishes).

Step

3.

Press START to begin testing. All Bad Boy luminaires connected to the main fixture (now

 

 

referred to as the "Master") will become "Slaves" and follow the test routine set on the

 

 

Master in an endless loop.

Step

4.

To stop the test sequence, press STOP on the Master.

While in group test, a Master can manually change certain values by using the Manual Control screen. From here, you can adjust the levels of parameters not active in the test sequence. For example, if a test were running on gobos and colors, you can adjust the pan and tilt to point the Master and all Slaves to a position where it will be easier see the output of the fixtures.

54

02.9812.0001C

Image 64
Contents Spot Luminaire Production Resource Group, LLC. All Rights Reserved Safety Notice Compliance Notice02.9812.0001C Iii Revision History This manual has been revised as followsTable of Contents Troubleshooting and Maintenance OperationRoutine Maintenance Appendix A. Technical SpecificationsAppendix B. Glossary Viii About This Manual IntroductionAdditional Documentation Customer Service PRG Dallas International Service PRG AtlantaGobo Art Submission Guidelines 02.9812.0001C Description Features FeaturesOverview Components Replacement Items and AccessoriesIncluded Items Major Components and Controls Bad Boy Luminaire External Components and ControlsInstallation Power and Data Cabling Requirements PowerData DMX512 CablesXLR 5-pin connectors should be wired as follows Recommended Cable TypesDMX512 Male Termination Connector Ethernet CablesUnpacking and Attaching Hanging Brackets Installation ProceduresTo unpack and attach brackets To install in standard 2-point hang Standard HangStandard Hanging Configuration and Dimensions To install in vertical hang Vertical Yoke Out HangVertical Yoke Out Hanging Configuration To install in a standing position Standing PositionConnecting Power and Data Data ConnectionsTo connect power and data 10 Connecting Power and Data CablesPowering Up the Luminaire Power Up and Basic Setup ProceduresTo power up Comm LED Operation Bypassing CalibrationTo bypass calibration DMX Comm Setting a Starting AddressTo program a starting address Ethernet Art-Net Comm 15 Selecting a Universe Ethernet ControlTo start lamp using Menu Touchscreen Lamp Operation SettingsStarting the Lamp Lamp Warm-UpConfiguring Universe, Comm, and Other Options Configuring Comm Loss SettingTo configure the Comm Loss setting To install follow spot handles Accessory OptionsFollow Spot Operation Using Control Channels Enabling Pan/Tilt Free ModeAt Pan/Tilt Menu Operation Using the Menu Touchscreen Screen Saver ModeMenu System NavigationOn-Board Battery Battery Wake SwitchMenu System Overview Menu System OverviewMenu Details Home ScreenConfiguration Screen Lamp ScreenPan/Tilt Screen Information ScreenCommunication Screen Status ScreenTest Screen Channel Mapping DMX512 OperationDMX512 Channel Mapping Wheel Control Wheel ControlGobo Wheel Color WheelsControl Channel Control Channels Control ChannelsTiming Channels Channel FunctionsTiming Channel Mapping Channel Function / Timing Channel RelationshipTiming Channels Timing Channels Timing Channels Gobo Set Zero Position Zoom TablesTo set zero position Troubleshooting Maintenance Troubleshooting Troubleshooting GuideErrors Mechanism Errors Other Errors Testing Test ScreenMechanical Test Group Test To perform a group testSoftware Update Software Update Using LumLoader ApplicationDownload the Software Software Crossload Equipment Handling Proper Lamp Servicing and OperationRoutine Maintenance Removing the Head CoversParts Tools and Supplies02.9812.0001C Removing the Aft Cover To remove Aft CoverRemoving the Enclosure Covers To remove Upper Enclosure CoversCleaning the Head Electrostatic Filters To clean head filtersTo clean enclosure intake filters Cleaning the Enclosure Intake FiltersTools and Supplies Parts Cleaning the Luminaire Exterior To clean luminaireCleaning the Lenses To clean lensesRemoving Front Glass Accessing Zoom Lens Assembly Cleaning Gobo, Color and Dimmer Wheels To clean gobo, color and dimmer wheelsReplacing the Lamp To replace lampReplacing the Lamp Adjusting the Lamp To adjust lampReplacing a Gobo To replace a gobo11 Replacing a Gobo 12 Gobo Positions and Alignment Replacing a Designer Color Filter To replace a designer color filterOpen 02.9812.0001C Technical Specifications Bad Boy Spot Luminaire ControlTechnical Specifications Bad Boy Road Case AC Line Current / Power vs. Voltage Photometric DataNarrow Zoom Iris Full Open 8º Full Angle 40,000 beam LumensMedium Zoom Iris Full Open 34º Full Angle 48,000 beam LumensWide Zoom Iris Full Open 56º Full Angle 50,000 beam Lumens8º, 34º and 56º Zoom settings Logarithmic Beam Illuminance Comparison02.9812.0001C Glossary Glossary of Terms Signal Movement of the luminaire around the axis of the tilt tube

02.9812.0001C specifications

Bad Boy Mowers has established itself as a premier manufacturer of innovative lawn care solutions, and the Bad Boy Mowers 02.9812.0001C model epitomizes their commitment to quality, performance, and user satisfaction. This commercial-grade mower is designed for those who take landscaping seriously, combining robust construction with advanced technologies.

One of the standout features of the 02.9812.0001C is its powerful engine, which typically boasts impressive horsepower, allowing it to tackle tough mowing tasks with ease. This model is engineered for longevity and reliability, ensuring that it can handle the demanding needs of professional landscapers as well as homeowners who want the very best for their lawns.

The 02.9812.0001C is designed with a wide cutting deck, often measuring 60 inches, allowing for efficient lawn coverage. This larger cutting width enables users to complete mowing tasks quicker, reducing the amount of time spent on the job. Additionally, the reinforced steel construction of the cutting deck provides durability and resilience, ensuring it can withstand the rigors of frequent use.

One of the key technologies incorporated into this model is its dual hydrostatic transmission system, which offers superior maneuverability and control. This feature allows users to easily navigate around obstacles and tight corners, providing a more precise mowing experience. The intuitive controls enhance the user experience, making it simple for operators of all skill levels to achieve desired results.

Another remarkable aspect of the Bad Boy Mowers 02.9812.0001C is its suspension system, which contributes to a smoother ride, reducing operator fatigue during extended use. This is especially beneficial when mowing uneven terrain, as the suspension effectively absorbs shocks and vibrations.

For enhanced comfort, the mower includes an ergonomic seat designed for maximum support, along with easy-to-reach controls for seamless operation. The model also features a commercial-quality air filtration system, ensuring optimal engine performance while extending maintenance intervals.

In summary, the Bad Boy Mowers 02.9812.0001C is an exceptional choice for those seeking a powerful, efficient, and user-friendly mower. With its advanced features, durable construction, and smart technologies, this model meets the demands of both professional landscapers and dedicated homeowners, making it a worthy investment for anyone serious about lawn care.