Chicago Electric 67648 Troubleshooting, Problem Possible Causes Likely Solutions

Page 18

Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

Tool will not start.

1.

Cord not connected.

1.

Check that cord is plugged in.

 

2.

No power at outlet.

2.

Check power at outlet. If outlet is

 

 

 

 

unpowered, turn off tool and check circuit

 

 

 

 

breaker. If breaker is tripped, make sure

 

 

 

 

circuit is right capacity for tool and circuit

 

 

 

 

has no other loads.

 

3.

Internal damage or wear. (Carbon

3.

Have technician service tool.

 

 

brushes or switch, for example.)

 

 

Tool operates slowly.

1. Excess pressure applied to workpiece.

1. Decrease pressure, allow tool to do the

 

 

 

 

work.

 

2.

Power being reduced by long or small

2.

Eliminate use of extension cord. If an

 

 

diameter extension cord.

 

extension cord is needed, use one with

 

 

 

 

the proper diameter for its length and load.

 

 

 

 

See Extension Cords in GROUNDING

 

 

 

 

section.

Performance

Carbon brushes worn or damaged.

Have qualified technician replace brushes.

decreases over time.

 

 

 

 

Excessive noise or

Internal damage or wear. (Carbon

Have qualified technician service tool.

rattling.

brushes or bearings, for example.)

 

 

Overheating.

1.

Forcing tool to work too fast.

1.

Allow tool to work at its own rate.

 

2.

Blocked motor housing vents.

2.

Wear ANSI-approved safety goggles and

 

 

 

 

NIOSH-approved dust mask/respirator

 

 

 

 

while blowing dust out of motor using

 

 

 

 

compressed air.

 

3.

Motor being strained by long or small

3.

Eliminate use of extension cord. If an

 

 

diameter extension cord.

 

extension cord is needed, use one with

 

 

 

 

the proper diameter for its length and load.

 

 

 

 

See Extension Cords in GROUNDING

 

 

 

 

section.

Tool does not grind,

1. Disc accessory may be loose on

1.

Check tightness of Outer Flange Arbor Nut

sand or wire brush

 

Spindle.

 

or threaded disc accessory on Spindle. Be

effectively.

 

 

 

sure disc accessory is of correct dimension

 

 

 

 

and Outer Flange Arbor Nut is tight.

 

2.

Disc accessory may be damaged, worn

2.

Check condition and type of disc

 

 

or wrong type for the material.

 

accessory. Use only proper type of disc

 

 

 

 

accessory in good condition.

Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.

Page 18

For technical questions, please call 1-800-444-3353.

SKU 67648

Image 18
Contents For technical questions or replacement parts, please call Angle GrinderContents General Power Tool Safety Warnings Save This ManualSave all warnings and instructions for future reference Increased risk of electric shock if your body is grounded Many accidents are caused by poorly maintained power tools Or arm may be pulled into the spinning accessory Kickback and Related Warnings Safety Warnings Specific for Grinding Operations Vibration Safety Safety Warnings Specific for Sanding OperationsSafety Warnings Specific for Wire Brushing Operations GroundingSee 3-Prong Plug and Outlet Extension CordsProng Plug and Outlet Outlets for 2-Prong Plug25’ 50’ 75’ 100’ 150’ SymbologyTable a SKU For technical questions, please callInstructions for putting Into use SpecificationsUnpacking ComponentsAssembly Installing the Wheel GuardInstalling the Auxiliary Handle Wheel From Tool Set UpOperating Instructions Wheel HereWork Piece and Work Area Set Up Overtightening can damage the wheel, causing wheel failureGeneral Operating Instructions Maintenance Servicing Cleaning, Maintenance, LubricationCarbon Brush 40 Replacement Accessory Storage and HandlingTroubleshooting Problem Possible Causes Likely SolutionsParts List Part Description QtyPart Description Assembly Diagram Limited 90 DAY Warranty