Grizzly owner manual Port Model T23096 Industrial 1⁄4 Die Grinder

Page 14

Symptom

Possible Cause

 

 

Solution

 

 

 

 

 

 

 

 

 

 

Tool does not

1.

Motor is at fault.

 

 

1.

Motor may be stuck in position

operate when the

 

 

 

 

 

 

from

improper

storage.

trigger is pressed,

 

 

 

 

 

 

Lubricate the air tool and rotate

but air runs freely

 

 

 

 

 

 

spindle by hand a few times.

from exhaust.

 

 

 

 

 

 

Next use the trigger to operate

 

 

 

 

 

 

 

the air tool while re-oiling

 

 

 

 

 

 

 

several times in the process to

 

 

 

 

 

 

 

flush the tool.

 

 

 

 

 

 

 

 

 

 

Tool runs slowly,

1.

Air regulator or tool

 

 

1.

Adjust the air regulator to 90

and only a small

 

adjustment is at fault.

 

 

PSI, or 100 PSI if the air hose is

amount of air exits

 

 

 

 

 

 

longer than 25 feet. Re-adjust

from the exhaust

 

 

 

 

 

 

the throttle valve screw to the

port.

 

 

 

 

 

 

fully open position.

 

 

 

 

2.

Trigger

throttle

valve

is

2.

Disassemble the throttle valve

 

 

obstructed.

 

 

 

and clean out sludge and

 

 

 

 

 

 

 

contaminants.

 

 

 

 

3.

Intake

filter screen

is

3.

Clean the filter screen behind

 

 

clogged.

 

 

 

 

the air supply fitting (see Figure

 

 

 

 

 

 

 

1, on Page 5).

 

 

 

 

4.

Motor loaded with

moisture

4.

Disassemble air tool, clean, and

 

 

or oil sludge.

 

 

 

relubricate. Lubricate

air

tool

 

 

 

 

 

 

 

and rotate spindle by hand a

 

 

 

 

 

 

 

few times. Next use the trigger

 

 

 

 

 

 

 

to operate the air tool, re-oiling

 

 

 

 

 

 

 

several times in the process to

 

 

 

 

 

 

 

flush the system.

 

 

 

 

 

 

 

 

Tool does

1.

Trigger bent or throttle valve

1.

Bend trigger back to its normal

not shut OFF

 

at fault.

 

 

 

 

position so throttle valve is free

when trigger is

 

 

 

 

 

 

to return to fully released or

released.

 

 

 

 

 

 

OFF position.

 

 

 

 

2.

Throttle valve stuck open.

 

2. Replace throttle valve spring or

 

 

 

 

 

 

 

O-rings.

 

 

 

 

 

 

 

 

 

 

 

Air tool becomes

1.

Air tool heats up from

1. Repair

air tool,

and

correct

hot or noisy

 

insufficient lubrication or

a

 

in-line

oiler

lubrication

during operation.

 

worn bearing.

 

 

 

adjustment, or follow

manual

 

 

 

 

 

 

 

lubrication requirements.

 

 

 

 

 

Air tool becomes

1.

The intake of moisture and

1. Keep compressor tank drained,

too cold to hold,

 

the pressure drop is causing

 

service,

reposition,

or

add

or ice crystals

 

moisture to freeze in the

 

additional water separators in

form at exhaust

 

tool.

 

 

 

 

the supply system.

 

 

 

port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-12-

Model T23096 Industrial 14" Die Grinder

Image 14
Contents Industrial 1⁄4 DIE Grinder Page Table of Contents Before Operating This Equipment SafetySafety Instructions for Pneumatic Tools Mation about proper operation of the equipmentAdditional Safety Instructions for Pneumatic Die Grinders Foreword Contact Info SpecificationsIntroduction Identification Air supply setup tips SetupUnpackingAssembly InventoryTo complete a typical cutting or grinding operation OperationsOperation Overview T20887 T20881 G6261 AccessoriesG8210-50-Pc. Stone Set H3105-Clamp Style Magnifying Lamp G7870 G7872 G7871 G7866 T21767G7867Periodically as required MaintenanceBefore and after each use Service TroubleshootingPort Model T23096 Industrial 1⁄4 Die Grinder Main Parts Diagram Main Parts List PartsWarranty