Apex Digital K1106 installation instructions Zones 1 8 System Controller, Control Board Loop

Page 21

Zones 1 - 8: System Controller

At default, all 8 system inputs are disabled. To enable a hardware input, enter a zone type in the zone type location.

Example: To enable Zone 1 (Input 1) and assign it as an Exterior Instant, enter 0647,000

Generally, this is all of the programming necessary to activate a zone. There are 4 spaces in each zone record to note a zone description. At the end of the zone programming section are detailed instructions for entering zone descriptions and a complete listing of the system vocabulary.

Other options:

Each input is defaulted to use a single End-Of-Line Resistor(EOLR). For certain installations, it may be necessary to use full 2-resistor supervision or for ease of installation, no EOLR. To adjust the supervision setting, enter the appropriate value in the supervision location.

OptionsValue

2 end-of-line resistor supervision .................................................................................................... 064

No end of line resistor (Not permitted in a UL installation) ............................................................. 128

Default (1 end-of-line resistor) ....................................................................................................... 000

Zone 1

 

Input

Control Board Loop 1

 

 

Option

Location

Default

New Value

 

Zone Type

0647

255

 

 

Option 1

0643

080

 

 

Option 2

0644

000

 

 

Supervision

1106

000

 

 

Word 1

 

Word 3

 

 

Word 2

 

Word 4

 

Zone 2

 

Input

Control Board Loop 2

 

 

 

Option

Location

Default

New Value

 

 

Zone Type

0663

255

 

 

 

Option 1

0659

080

 

 

 

Option 2

0660

000

 

 

 

Supervision

1110

000

 

 

 

Word 1

 

Word 3

 

 

 

Word 2

 

Word 4

 

 

 

Zone 3

 

 

Input

Control Board Loop 3

 

Option

Location

Default

New Value

Zone Type

0679

255

 

Option 1

0675

080

 

Option 2

0676

000

 

Supervision

1114

000

 

Word 1

 

Word 3

 

Word 2

 

Word 4

 

Zone 4

 

Input

Control Board Loop 4

 

 

 

Option

Location

Default

New Value

 

 

Zone Type

0695

255

 

 

 

Option 1

0691

080

 

 

 

Option 2

0692

000

 

 

 

Supervision

1118

000

 

 

 

Word 1

 

Word 3

 

 

 

Word 2

 

Word 4

 

 

Zone 5

Input

Control Board Loop 5

 

Option

Location

Default

New Value

Zone Type

0711

255

 

Option 1

0707

080

 

Option 2

0708

000

 

Supervision

1122

000

 

Word 1

 

Word 3

 

Word 2

 

Word 4

 

Zone 6

Input

Control Board Loop 6

 

Option

Location

Default

New Value

Zone Type

0727

255

 

Option 1

0723

080

 

Option 2

0724

000

 

Supervision

1126

000

 

Word 1

 

Word 3

 

Word 2

 

Word 4

 

Zone 7

Input

Control Board Loop 7

 

Option

Location

Default

New Value

Zone Type

0743

255

 

Option 1

0739

080

 

Option 2

0740

000

 

Supervision

1130

000

 

Word 1

 

Word 3

 

Word 2

 

Word 4

 

 

Zone 8

 

 

Input

Control Board Loop 8

 

Option

Location

Default

New Value

Zone Type

0759

255

 

Option 1

0755

080

 

Option 2

0756

000

 

Supervision

1134

000

 

Word 1

 

Word 3

 

Word 2

 

Word 4

 

21

Image 21
Contents Destiny Page Page Panel Software Revision History Software RevisionsTable of Contents Specifications Page Items Included With the Control Panel Mounting the Control Board Inserting the Cabinet LockSmoke Power Trigger to output Wiring DiagramWiring Notes System Terminals Action Power LED Wiring an Input Using an End-of-Line Resistor Wiring an Input Using 2 End-of-Line Resistor SupervisionWiring an Input Using No End-of-Line Resistors Programming Program Mode Exiting Program ModeLocations and Values WHT Quick StartControl Board Loop Using This ManualSystem Setup Programming Zones These Options are Common to Each Zone Section Zone TypeZone Options Control Board Loop Zones 1 8 System ControllerZones 10 23 Alarm Type Transmitters Zone 9 System Controller Two-Wire Smoke Loop128 Zones 24 25 Portable Transmitters Zones 18 23 Alarm Type Transmitters5801 5804 Zone 26 System Keypads Zone 27 Local PhoneZone 28 Remote Phone / Phone Line Monitor System Access Codes Zone 29 Monitor Trouble ConditionsUser Code + Digit Functions Assigning Words to Zones Automated Programming LocationsWord Location VocabularyUser Code Options System Times And Other OptionsSystem Options Group Monitor Trouble Conditions Bypass OptionsExtended Monitor Zone Type Assignment System Triggers Option Enter Total Value Activation Action System Triggers OptionAutomated Event Memory Log Upload Automatic Communicator TestingFail To Open Disarm / Fail to Close Arm Automatic Arming and DisarmingReporting Format Two-Way Voice Options Ademco Contact ID Report Codes Report Codes Dialer OptionsReport Type Location Value Open Disarm Glossary of Terms With keypads and phone Following are system operation notes relative to bypass Status messages at the keypad Arming reports to the central station A UL installation Speaker Applications Single digit hexadecimal activation type Set Time and Date Dial Station Armed Spoken, but also the description of the zone that caused it Page Page Federal Communications Commission FCC Part 15 Statement Installation Layout Limitations of this Alarm System Ademco Limited Warranty

K1106 specifications

The Apex Digital K1106 is a versatile and compact multimedia player that has gained recognition for its user-friendly interface and impressive range of features. Designed to cater to the needs of modern consumers, the K1106 seamlessly blends function with style, making it an appealing choice for entertainment enthusiasts.

One of the standout features of the Apex Digital K1106 is its support for multiple media formats. Users can enjoy a variety of audio and video files, including popular formats such as MP3, WMA, AVI, and MKV, ensuring compatibility with a wide range of content. This flexibility allows users to play their favorite movies, music, and photos without the hassle of converting files, making it an all-in-one solution for home entertainment.

The K1106 also integrates advanced connectivity options, including HDMI, USB, and composite outputs. The HDMI output delivers high-definition video and audio, creating an immersive viewing experience when connected to HDTVs or projectors. Additionally, the USB port allows users to connect flash drives or external hard drives, making it easy to access a library of multimedia content. The composite output ensures compatibility with older television models, widening its usability across various devices.

Another key characteristic of the Apex Digital K1106 is its user-friendly interface. With an intuitive remote control and on-screen menu, navigating through various options and settings is straightforward, promoting an enjoyable user experience. The compact design of the device is also noteworthy, allowing it to fit seamlessly into any entertainment setup without taking up excessive space.

The device offers various playback features, such as pause, resume, and chapter selection, giving users the flexibility to enjoy their media at their own pace. Moreover, the K1106 supports subtitle files, enhancing the viewing experience for international content or dialogue-heavy films.

In summary, the Apex Digital K1106 is a multifaceted multimedia player that stands out for its broad format compatibility, advanced connectivity options, user-friendly interface, and playback features. Whether for watching movies, listening to music, or viewing photos, this device meets the diverse entertainment needs of its users while maintaining a sleek and compact design. Its combination of technology and practicality makes it a valuable addition to any home entertainment system, appealing to both casual viewers and avid media lovers alike.