Apex Digital K1106 installation instructions Ademco Contact ID Report Codes

Page 38

Ademco Contact ID Report Codes

APEX Description

Code Sent to Central Station

ADEMCO Description

Exterior instant

E 131

Z ............................................Perimeter burglary

Exterior delay 1

E 134

Z ............................................Entry/exit burglary

Exterior delay 2

E 134

Z ............................................Entry/exit burglary

Interior instant

E 132

Z ............................................Interior burglary

Interior delay 1

E 132

Z ............................................Interior burglary

Interior delay 2

E 132

Z ............................................Interior burglary

Fire

E 110

Z ............................................Fire alarm

Panic

E 120

Z ............................................Panic alarm

Silent panic

E 122

Z ............................................Silent

Emergency

E 100

Z ............................................Medical

Follower

E 132

Z ............................................Interior burglary

Auxiliary

E 150

Z ............................................24 hour nonburglary

Duress disarm

E 121

0

............................................Duress

Duress when not armed

E 121

0

............................................Duress

Zone restore after activation

R 140

Z ............................................General Alarm

Transmitter low battery

E 384

Z ............................................RF low battery

Transmitter battery restore

R 384

Z ............................................RF low battery

Zone trouble

E 370

Z ............................................Protection loop

Zone trouble restore

R 370

Z ............................................Protection loop

High current trouble

E 300

91

..........................................System trouble

High current restore

R 300

91

..........................................System trouble

Phone line restore

R 350

28

..........................................Communication

Open (disarm)

E 401

U

...........................................Open by user

Open after activation

E 450

U

...........................................Exception open

Close (arm)

R 401

U

...........................................Close by user

Force Arm

R 450

U

...........................................Exception close

Control low battery

E 302

29

..........................................Low system battery

Control battery restore

R 302

29

..........................................Low system battery

AC fail

E 301

29

..........................................AC loss

AC restore

R 301

29

..........................................AC loss

User communicator test

E 601

Z ............................................Manual trigger test

Automatic communicator test

E 602

99

..........................................Periodic test report

Cancel

E 406

Z ............................................Cancel

Zone bypass

E 570

Z ............................................Zone bypass

Zone unbypass

R 570

Z ............................................Zone bypass

Day zone trouble

E 135

Z ............................................Day alarm

Day zone trouble restore

R 135

Z ............................................Day alarm

Upload/download attempt

E 412

99

..........................................Success - download/access

Program mode entry

E 627

99

..........................................Program mode entry

Fail to open

E 453

99

..........................................Failed to open

Fail to close

E 454

99

..........................................Failed to close

Zone open

E 371

Z ............................................Protection Loop

Zone restore

R 371

Z ............................................Protection Loop

Tamper

E 383

Z ............................................Zone tamper

Tamper Restore

R 383

Z ............................................Zone tamper restore

Receiver Supervision Trouble

............

E 355

Z ............................................Loss of radio supervision

Receiver Supervision Trouble Restore R 355

Z ............................................Loss of radio supervision

38

Image 38
Contents Destiny Page Page Software Revisions Panel Software Revision HistoryTable of Contents Specifications Page Items Included With the Control Panel Inserting the Cabinet Lock Mounting the Control BoardWiring Diagram Smoke Power Trigger to outputWiring Notes System Terminals Action Power LED Wiring an Input Using No End-of-Line Resistors Wiring an Input Using an End-of-Line ResistorWiring an Input Using 2 End-of-Line Resistor Supervision Locations and Values Programming Program ModeExiting Program Mode Quick Start WHTUsing This Manual Control Board LoopSystem Setup Zone Options Programming ZonesThese Options are Common to Each Zone Section Zone Type Zones 1 8 System Controller Control Board LoopZone 9 System Controller Two-Wire Smoke Loop Zones 10 23 Alarm Type Transmitters128 Zones 18 23 Alarm Type Transmitters Zones 24 25 Portable Transmitters5801 5804 Zone 28 Remote Phone / Phone Line Monitor Zone 26 System KeypadsZone 27 Local Phone User Code + Digit Functions System Access CodesZone 29 Monitor Trouble Conditions Automated Programming Locations Assigning Words to ZonesVocabulary Word LocationSystem Times And Other Options User Code OptionsSystem Options Group Extended Monitor Zone Type Assignment Monitor Trouble ConditionsBypass Options System Triggers System Triggers Option Option Enter Total Value Activation ActionAutomatic Communicator Testing Automated Event Memory Log UploadReporting Format Fail To Open Disarm / Fail to Close ArmAutomatic Arming and Disarming Two-Way Voice Options Ademco Contact ID Report Codes Dialer Options Report CodesReport Type Location Value Open Disarm Glossary of Terms With keypads and phone Following are system operation notes relative to bypass Status messages at the keypad Arming reports to the central station A UL installation Speaker Applications Single digit hexadecimal activation type Set Time and Date Dial Station Armed Spoken, but also the description of the zone that caused it Page Page Federal Communications Commission FCC Part 15 Statement Installation Layout Limitations of this Alarm System Ademco Limited Warranty

K1106 specifications

The Apex Digital K1106 is a versatile and compact multimedia player that has gained recognition for its user-friendly interface and impressive range of features. Designed to cater to the needs of modern consumers, the K1106 seamlessly blends function with style, making it an appealing choice for entertainment enthusiasts.

One of the standout features of the Apex Digital K1106 is its support for multiple media formats. Users can enjoy a variety of audio and video files, including popular formats such as MP3, WMA, AVI, and MKV, ensuring compatibility with a wide range of content. This flexibility allows users to play their favorite movies, music, and photos without the hassle of converting files, making it an all-in-one solution for home entertainment.

The K1106 also integrates advanced connectivity options, including HDMI, USB, and composite outputs. The HDMI output delivers high-definition video and audio, creating an immersive viewing experience when connected to HDTVs or projectors. Additionally, the USB port allows users to connect flash drives or external hard drives, making it easy to access a library of multimedia content. The composite output ensures compatibility with older television models, widening its usability across various devices.

Another key characteristic of the Apex Digital K1106 is its user-friendly interface. With an intuitive remote control and on-screen menu, navigating through various options and settings is straightforward, promoting an enjoyable user experience. The compact design of the device is also noteworthy, allowing it to fit seamlessly into any entertainment setup without taking up excessive space.

The device offers various playback features, such as pause, resume, and chapter selection, giving users the flexibility to enjoy their media at their own pace. Moreover, the K1106 supports subtitle files, enhancing the viewing experience for international content or dialogue-heavy films.

In summary, the Apex Digital K1106 is a multifaceted multimedia player that stands out for its broad format compatibility, advanced connectivity options, user-friendly interface, and playback features. Whether for watching movies, listening to music, or viewing photos, this device meets the diverse entertainment needs of its users while maintaining a sleek and compact design. Its combination of technology and practicality makes it a valuable addition to any home entertainment system, appealing to both casual viewers and avid media lovers alike.