e.CAPWAP UDP ports must not be blocked in the network.

f.The access point must be able to find the IP address of the controller. This can be accomplished using DHCP, DNS, or IP subnet broadcast. This guide describes the DHCP method to convey the controller IP address. For other methods, refer to the product documentation. See also the “Using DHCP Option 43” section on page 13 for more information.

Step 2 Apply power to the access point:

a.The access point is 802.3af (15.4 W) compliant and can be powered by any of the following 802.3af compliant devices:

2106 controller

WS-C3550, WS-C3560, and WS-C3750 switches

C1880 switch

2600, 2610, 2611, 2621, 2650, and 2651 multiservice platforms

2610XM, 2611XM, 2621XM, 2650XM, 2651XM, and 2691 multiservice platforms

2811, 2821, and 2851 integrated services routers

3620, 3631-telco, 3640, and 3660 multiservice platforms

3725 and 3745 multiservice access routers

3825 and 3845 integrated services routers

The recommended external power supply for the access point is the Cisco AIR-PWR-B power supply. The access point can also be powered by the following optional external power sources:

1250 series access point power injector (AIR-PWRINJ4)

Any 802.3af compliant power injector

Note The 3502P access point requires a Gigibit Ethernet link to prevent the Ethernet port from becoming a bottleneck for traffic because wireless traffic speeds exceed transmit speeds of a 10/100 Ethernet port.

b.As the access point attempts to connect to the controller, the LEDs cycle through a green, red, and amber sequence, which can take up to 5 minutes.

Note If the access point remains in this mode for more than five minutes, the access point is unable to find the Master Cisco wireless LAN controller. Check the connection between the access point and the Cisco wireless LAN controller and be sure that they are on the same subnet.

10

Image 10
Contents Cisco Aironet 3502P Lightweight Access Point Safety Instructions About this GuideUnpacking 20A. StatementAccess Point Ports and Connections top OverviewAccess Point Ports and Connections bottom Configuring the Access Point Controller Discovery ProcessPreparing the Access Point Installation Summary Performing a Pre-Installation ConfigurationPre-Installation Configuration Setup Controller Layer 3 devices Cisco Aironet access pointsPage Page Mounting the Access Point Deploying the Access Point on the Wireless NetworkTroubleshooting Using Dhcp OptionChecking the Access Point LED LEDLED Troubleshooting the Access Point Join Process Declarations of Conformity and Regulatory Information Models Vcci Statement for Japan Japanese Translation English TranslationIndustry Canada Statement 371-Power Cable and AC AdapterCanadian Compliance Statement Déclaration de conformité pour le Canada Page Page Canada Declaration of Conformity for RF ExposureUnited States European UnionDeclaration of Conformity Statements AustraliaAccess Point Specifications Add the option 60 line using the following syntaxCategory Specification Page USA