Sanyo SPW-XR254EH56 Installing the Ceiling Panel, When Removing the Ceiling Panel for Servicing

Page 10

2-7. Installing the Ceiling Panel

(1)Lift the ceiling panel and position it to align the panel hook with the panel catch of the indoor unit.

(5)Install the air filter and air-intake grille by perform- ing the steps in section 2-6 in reverse.

NOTE

The ceiling panel must be mounted in the correct direction. Note that the 2 catches of the panel differ in size.

Confirm that the catches are correctly matched be- tween the ceiling panel and the indoor unit body.

(2)Next, check to see that the ceiling panel is prop- erly aligned with the seamline of the ceiling. If it is not, remove the ceiling panel and slightly readjust the indoor unit body to the proper suspension point.

(3)When the ceiling panel has been properly aligned, use the supplied 4 mounting screws (M5) with washers to permanently fasten the ceiling panel.

(4)Install the wiring connector from the ceiling panel to the connector in the electrical component box of the indoor unit. After installing the connector, use the clamp on the body of the indoor unit to secure the wiring.

NOTE

Rehook the safety string before closing the air-intake grille.

2-8. When Removing the Ceiling Panel for Servicing

When removing the ceiling panel for servicing, remove the air-intake grille and air filter, disconnect the wiring connector inside the electrical component box, and then remove the 4 mounting screws.

Unit body

Ceiling panel

Panel catch

Panel catch

Electrical(arrange facing downwards) component box

Electrical component box

Clamp

Ceiling panel wiring connector

(2 locations)

Screws M5 with washer (supplied)

Air filter

Air-intake grille

1973_X_I

Fig. 2-15

10

Image 10
Contents Optional Controllers SPW-XR254EH56 SPW-XR364EH56 SPW-XR484EH56Outdoor Units Sanyo Airconditioners Europe S.r.lSpecial Precautions Check of Density Limit Contents GeneralSuspending the Indoor Unit HOW to Install the Indoor UnitPreparation for Suspending Placing the Unit Inside the Ceiling Do not install the pipe with an upward Installing the Drain PipingDo not install an air Backwards and leak when the unit isBe careful since the fan will Checking the DrainageTo mount the tube cover Latch Screw Air intake grille Ceiling panel Installing the Ceiling Panel When Removing the Ceiling Panel for ServicingInstalling the air-intake plenum AccessoriesInstallation Installing the duct connection boxDuct Connection Flange Duct connection box General Precautions on Wiring Electrical WiringUse shielded wiring Wiring System Diagrams 7P terminal boardOutdoor unit Indoor unit How to connect wiring to the terminal For stranded wiring Driver. FigFlaring Procedure with a Flare Tool HOW to Process TubingConnecting the Refrigerant Tubing Use of the Flaring Method DeburringTube diameter Tightening torque Tube thickness Approximate · cm 140 180 kgf Φ9.52 3/8Insulation material Precautions for Packed Valve OperationInsulating the Refrigerant Tubing Tubing Insulation After a tube has been insu Lated, never try to bend itFinishing the Installation Taping the TubesHow to remove the filter Care and CleaningHow to clean the filter Name of Parts Indoor UnitTroubleshooting Tips for Energy SavingPosants internes et provoquer des décharges électriques Nom des pièces unité intérieureEntretien et nettoyage Type PériodePoussière ou de la suie Comment retirer le filtreRité crochez-la à la grille après ces opérations Entretien avant une période d’inactivité prolongéeConseils pour économiser l’énergie Guide de dépannageChoses à faire Es außerdem vom Netz zu trennen Bezeichnungen der TeilePflege und Reinigung Besonders vorsichtig seinZeit nicht verwendet wurde Herausnehmen des FiltersAbgeschlossen haben Zeit nicht verwendet werden sollFehlersuche Nützliche Hinweise für EnergieeinsparungNome delle parti Unità interna Cura e manutenzioneRimozione del filtro LavoroPrima di chiamare il tecnico Suggerimenti per risparmiare energiaNomenclatura das peças unidade interior Cuidados e limpezaEstas peças Como remover o filtroNar todas as tarefas Estão bloqueadas com sujidade ou fuligemResolução de problemas Sugestões para poupar energiaGreek Greek Greek Cuidados y limpieza Nombres de las partes unidad interiorCómo limpiar el filtro Cómo extraer el filtro Localización de averías Sugerencias para ahorrar energía

SPW-XR254EH56 specifications

The Sanyo SPW-XR254EH56 is a cutting-edge air conditioning unit designed for both residential and commercial applications, offering reliable performance along with advanced features. This model is part of Sanyo’s commitment to providing energy-efficient climate control solutions that ensure comfort while minimizing environmental impact.

One of the standout features of the SPW-XR254EH56 is its high energy efficiency rating. It incorporates advanced inverter technology that allows the system to automatically adjust its cooling and heating output based on the current demand. This ensures that the unit operates at optimal levels, significantly reducing energy consumption and costs. The inverter also helps maintain a consistent temperature within the space, enhancing comfort while preventing the temperature fluctuations commonly associated with traditional units.

In terms of cooling capability, the SPW-XR254EH56 boasts impressive performance metrics. It is designed to efficiently cool medium to large spaces, making it ideal for offices, conference rooms, or larger homes. The unit features a multi-directional airflow system that promotes even distribution of cool air throughout the room, ensuring that every corner is comfortably conditioned.

The Sanyo SPW-XR254EH56 also comes equipped with a range of smart technologies. Its integrated Wi-Fi capability allows users to monitor and control the unit remotely via a smartphone app. This feature enables scheduling, temperature adjustments, and energy usage tracking, offering convenience and enhancing user experience. Additionally, the model includes a programmable timer that further supports energy savings by allowing users to set specific operating times based on their routines.

Noise reduction is another key feature of the SPW-XR254EH56. The unit operates quietly, making it suitable for environments where sound levels need to be kept to a minimum, such as bedrooms or quiet office spaces.

Moreover, the SPW-XR254EH56 is designed with a sleek, modern aesthetic that can seamlessly blend into various interiors. Its durable and compact design not only enhances visual appeal but also ensures reliability and longevity.

In summary, the Sanyo SPW-XR254EH56 stands out for its energy efficiency, advanced inverter technology, smart capabilities, quiet operation, and sleek design, making it an excellent choice for those seeking a dependable and modern air conditioning solution.