Sanyo SPW-XR254EH56 operation manual Name of Parts Indoor Unit, Care and Cleaning, Type Period

Page 21

5. APPENDIX

Name of Parts (Indoor Unit)

Water drain

Ceiling panel (optional)

Air outlet

(4 locations)

Air intake grille (air intake)

Care and Cleaning

WARNING

1.For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.

2.Do not pour water on the indoor unit to clean it. This will damage the internal compo- nents and cause an electric shock hazard.

Air intake and outlet side Clean the air intake and outlet side of the indoor unit with a vacuum cleaner brush, or wipe them (Indoor unit) with a clean, soft cloth.

If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When clean- ing the air outlet side, be careful not to force the vanes out of place.

CAUTION

1.Never use solvents or harsh chemicals when cleaning the indoor unit. Do not wipe plastic parts using very hot water.

2.Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts.

3.The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center.

Air filter The air filter collects dust and other particles from the air and should be cleaned at regular intervals as indicated in the table below or when the filter indication ( ) on the display of the remote control unit (wired type) shows that the filter needs cleaning. If the filter gets blocked, the efficiency of the air conditioner drops greatly.

Type

Period

X

Six months

NOTE

The frequency with which the filter should be cleaned depends on the environment in which the unit is used.

<How to clean the filter>

1.Remove the air filter from the air intake grille.

2.Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it.

<How to remove the filter>

1.Use a screwdriver to remove the bolt screw on each side for the two latches. (Be sure to reattach the two bolt screws after cleaning.).

2.Press on the two latches of the air intake grille with your thumbs in the direction of the arrow to open the grille.

3.Open the air intake grille downward.

CAUTION

When cleaning the air filter, never remove the safety chain. If it is necessary to remove it for servicing and maintenance inside, be sure to reinstall the safety chain securely (hook on the grille side) after the work.

When the filter has been removed, rotating parts (such as the fan), electrically charged areas, etc. will be exposed in the unit’s opening. Bear in mind the dangers that these parts and areas pose, and proceed with the work carefully.

21

Image 21
Contents Outdoor Units SPW-XR254EH56 SPW-XR364EH56 SPW-XR484EH56Optional Controllers Sanyo Airconditioners Europe S.r.lSpecial Precautions Check of Density Limit General ContentsHOW to Install the Indoor Unit Suspending the Indoor UnitPreparation for Suspending Placing the Unit Inside the Ceiling Do not install an air Installing the Drain PipingDo not install the pipe with an upward Backwards and leak when the unit isChecking the Drainage Be careful since the fan willTo mount the tube cover Latch Screw Air intake grille Ceiling panel When Removing the Ceiling Panel for Servicing Installing the Ceiling PanelInstallation AccessoriesInstalling the air-intake plenum Installing the duct connection boxDuct Connection Flange Duct connection box Electrical Wiring General Precautions on WiringUse shielded wiring 7P terminal board Wiring System DiagramsOutdoor unit Indoor unit Driver. Fig How to connect wiring to the terminal For stranded wiringConnecting the Refrigerant Tubing Use of the Flaring Method HOW to Process TubingFlaring Procedure with a Flare Tool Deburring· cm 140 180 kgf Φ9.52 3/8 Tube diameter Tightening torque Tube thickness ApproximateInsulating the Refrigerant Tubing Tubing Insulation Precautions for Packed Valve OperationInsulation material After a tube has been insu Lated, never try to bend itTaping the Tubes Finishing the InstallationHow to clean the filter Care and CleaningHow to remove the filter Name of Parts Indoor UnitTips for Energy Saving TroubleshootingEntretien et nettoyage Nom des pièces unité intérieurePosants internes et provoquer des décharges électriques Type PériodeRité crochez-la à la grille après ces opérations Comment retirer le filtrePoussière ou de la suie Entretien avant une période d’inactivité prolongéeGuide de dépannage Conseils pour économiser l’énergieChoses à faire Pflege und Reinigung Bezeichnungen der TeileEs außerdem vom Netz zu trennen Besonders vorsichtig seinAbgeschlossen haben Herausnehmen des FiltersZeit nicht verwendet wurde Zeit nicht verwendet werden sollNützliche Hinweise für Energieeinsparung FehlersucheCura e manutenzione Nome delle parti Unità internaLavoro Rimozione del filtroSuggerimenti per risparmiare energia Prima di chiamare il tecnicoCuidados e limpeza Nomenclatura das peças unidade interiorNar todas as tarefas Como remover o filtroEstas peças Estão bloqueadas com sujidade ou fuligemSugestões para poupar energia Resolução de problemasGreek Greek Greek Nombres de las partes unidad interior Cuidados y limpiezaCómo limpiar el filtro Cómo extraer el filtro Sugerencias para ahorrar energía Localización de averías

SPW-XR254EH56 specifications

The Sanyo SPW-XR254EH56 is a cutting-edge air conditioning unit designed for both residential and commercial applications, offering reliable performance along with advanced features. This model is part of Sanyo’s commitment to providing energy-efficient climate control solutions that ensure comfort while minimizing environmental impact.

One of the standout features of the SPW-XR254EH56 is its high energy efficiency rating. It incorporates advanced inverter technology that allows the system to automatically adjust its cooling and heating output based on the current demand. This ensures that the unit operates at optimal levels, significantly reducing energy consumption and costs. The inverter also helps maintain a consistent temperature within the space, enhancing comfort while preventing the temperature fluctuations commonly associated with traditional units.

In terms of cooling capability, the SPW-XR254EH56 boasts impressive performance metrics. It is designed to efficiently cool medium to large spaces, making it ideal for offices, conference rooms, or larger homes. The unit features a multi-directional airflow system that promotes even distribution of cool air throughout the room, ensuring that every corner is comfortably conditioned.

The Sanyo SPW-XR254EH56 also comes equipped with a range of smart technologies. Its integrated Wi-Fi capability allows users to monitor and control the unit remotely via a smartphone app. This feature enables scheduling, temperature adjustments, and energy usage tracking, offering convenience and enhancing user experience. Additionally, the model includes a programmable timer that further supports energy savings by allowing users to set specific operating times based on their routines.

Noise reduction is another key feature of the SPW-XR254EH56. The unit operates quietly, making it suitable for environments where sound levels need to be kept to a minimum, such as bedrooms or quiet office spaces.

Moreover, the SPW-XR254EH56 is designed with a sleek, modern aesthetic that can seamlessly blend into various interiors. Its durable and compact design not only enhances visual appeal but also ensures reliability and longevity.

In summary, the Sanyo SPW-XR254EH56 stands out for its energy efficiency, advanced inverter technology, smart capabilities, quiet operation, and sleek design, making it an excellent choice for those seeking a dependable and modern air conditioning solution.