Jet Tools JDS-12B owner manual Disconnect the machine from the power source

Page 6

230 Volt Operation

If 230V, single phase operation is desired, the following instructions must be followed:

1.Disconnect the machine from the power source.

2.This JET sander is supplied with four motor leads that are connected for 115V operation, as shown in Figure A. Reconnect these four motor leads for 230V operation, as shown in Figure B.

3.The 115V attachment plug (A), supplied with the sander, must be replaced with a UL/CSA listed plug suitable for 230V operation (D). Contact your local Authorized JET Service Center or qualified electrician for proper procedures to install the plug. The sander must comply with all local and national codes after the 230 volt plug is installed.

4.The sander with a 230 volt plug should only be connected to an outlet having the same configuration

(D). No adapter is available or should be used with the 230 volt plug.

Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly grounded. If you are not sure, have a registered electrician check the receptacle.

6

Image 6
Contents JDS-12B Benchtop 12 Disc Sander Warranty & Service Volts Total Length of Cord in Feet AWGPage Grounding Instructions Volt OperationDisconnect the machine from the power source Specifications Table of ContentsContents of the Shipping Carton Tools Required for Assembly & AdjustmentsUnpacking Stand Assembly optional accessory Sander AssemblyTable Adjustment Sanding Disc ReplacementDisconnect machine from the power source Filler Bar On/Off SwitchCenter Point BrakeCanister Filter optional accessory Cleaning the FilterOptional Accessories Troubleshooting Possible Cause Solution Disc Sander Breakdown Parts List For The JDS-12B Benchtop Disc Sander Index Part Description Size QtyOptional Accessory OS12DS-HK Wiring Diagram