Sanyo SAP-KRV123EH, SAP-KRV93EH Adjusting the Airflow Direction, Cool Sweep DRY FAN Heat

Page 72

Adjusting the Airflow Direction

1. Horizontal

CAUTION

The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right.

When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down.

2.Vertical The vertical airflow can be adjusted by moving the flap with the remote control unit. Do not move the flap with your hands. Confirm that the remote control unit has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.

A. Sweep function

The flap starts moving up and down to deliver air over the sweep range.

C. Auto flap function

The flap is set to the recommended position.

COOL

SWEEP

DRY

FAN

SWEEP

HEAT

B. Setting the airflow manually

Referring to the above illustration, use the FLAP button to set the airflow direction within the range used during the heating, cooling, or dehumidifying operation.

NOTE

CAUTION

The flap automatically closes when the unit is off.

During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position ) until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote control.

Use the FLAP button on the remote control to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote control and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again.

Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down.

OI-671-21EG

21

 

Image 72
Contents DC Inverter Split System AIR Conditioner Please Read Before Starting Table of Contents Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeSpecifications Unit SpecificationsIndoor Unit SAP-KRV93EHSAP-KRV123EH Outdoor Unit SAP-CRV123EHMajor Component Specifications SAP- KRV93EHSAP- KRV123EH Outdoor Unit Outdoor Unit SAP- CRV93EHOutdoor Unit SAP- CRV123EH Other Component Specifications Indoor Unit SAP- KRV93EHSAP- CRV123EH Data Ø65SAP-CRV123EH AIR DischargeRefrigerant Flow Diagram Refrigerant Flow DiagramInsulation of Refrigerant Tubing Proper insulation material. The thickness of the insulationTemperature Charts Performance DataIndoor Unit SAP-KRV93EH Outdoor Unit SAP-CRV93EH Indoor Unit SAP-KRV123EH Outdoor Unit SAP-CRV123EH Indoor Air TempAir Throw Distance Charts Axis air Vertical Operating Frequency Charts 230V Single-phase 50HzIndoor Unit SAP- KRV93EH Outdoor Unit SAP- CRV93EH CoolingHeating Indoor Unit SAP- KRV123EH Heating Electrical Data Electric Wiring Diagrams Outdoor Unit Indoor UnitSAP-CRV93EH SAP-KRV93EH SAP-CRV123EH SAP-KRV123EH Indoor Unit SAP-KRV123EHInstallation Instructions Installation Site SelectionAvoid Out Recommended Wire Length and Diameter Wiring System DiagramRemote Control Unit Installation Position To take out the remote control unit, pull it forwardHow to Test Run the Air Conditioner Remove the Grille to Install the Indoor Unit Maintenance Address Setting of the Remote Control UnitHow to Disconnect Emergency operation Auto cooling/heating operationPAM-αcontrol Timer backup Lamp colorsCompressor discharge temperature control Overload prevention during heatingFreeze prevention Cold-air prevention during heatingDefrost detection and release CT Peak current cut-off controlPrecautions before performing inspection or repair Method of self-diagnosticsExecuting self-diagnostics S01 S02S03 S04If self-diagnostics function fails to operate Checking the outdoor unitChecking serial communications NormalDiagnostic procedure Diagnostic resultsRemedy for symptom 3 to Measurement location Normal valueNoise malfunction and electromagnetic interference Noise malfunctionElectromagnetic interference Checking Electrical Components Measurement of Insulation ResistanceChecking Continuity of Fuse on PCB Ass’y Refrigerant R410A Special Precautions When Servicing Unit Characteristics of New Refrigerant R410AChecklist Before Servicing HFC32 50% / HFC125 50%Tubing precautions No addition of compressor oil for R410ANo use of refrigerant other than R410A If refrigerant R410A is exposed to fireTubing Installation Procedures Tools Specifically for R410ACase of Compressor Malfunction Configuration and characteristics of cylinders RechargingUnit. This may cause dam- age to the compressor ExampleCase Refrigerant is Leaking Welding leaking pointsCharging Additional Refrigerant Retro-Fitting Existing SystemsOI-852-6-4180-671-00-0 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit Unit Display and Operation Button Remote Control Unit Display Remote Control Unit Hour OFF TimerOn Time Auto HeatDRY CoolUsing the Remote Control Unit Temperature Display SelectorHow to Install Batteries Button Time Display Selector buttonUsing the Remote Control Unit Rear side Remote control unit mountMounting screws 4 x 16 included HoleOperation with the Remote Control Unit StepPress the ON/OFF operation button Operation with the Remote Control Unit Manual OperationAdjusting the Fan Speed Night Setback Mode is used for saving energy Cooling and DRY ModeSetting TemperatureQuiet Mode Special Remarks Setting the Timer Operation IndicationSetting the Timer To cancel a timer program Press the Cancel button1030 pm 710 am 1100 am Present time OFFUsing the 1-Hour OFF Timer Setting procedureCancellation procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction Cool Sweep DRY FAN HeatOperation without the Remote Control Unit Care and CleaningWhen the air conditioner is not running Care and Cleaning Air intake grille Anti-mold filter CleaningSuffocation in extreme cases FilterTroubleshooting Operating RangeTrouble Possible Cause Remedy Osaka, Japan SM700590 FEB/2004
Related manuals
Manual 25 pages 39.04 Kb

SAP-CRV93EH, SAP-CRV123EH, SAP-KRV93EH, SAP-KRV123EH specifications

The Sanyo SAP-KRV93EH and SAP-KRV123EH are innovative air conditioning units that stand out in the market for their performance, energy efficiency, and user-friendly features. Designed to cater to various cooling needs, these models are suitable for both residential and commercial spaces, ensuring comfort in every environment.

One of the main features of both models is their advanced inverter technology. This technology allows the air conditioners to adjust the compressor speed according to the desired temperature, offering precise climate control while significantly reducing energy consumption. This not only translates to lower electricity bills but also minimizes the environmental impact, making the SAP-KRV93EH and SAP-KRV123EH eco-friendly options.

The SAP-KRV93EH has a cooling capacity of 9,000 BTU, while the SAP-KRV123EH boasts an impressive 12,000 BTU. This range ensures that users can choose the appropriate unit according to the size of the room or area requiring cooling. The units are equipped with high-efficiency filters that purify the air, removing dust, allergens, and other particulates. This feature is particularly beneficial for those with allergies or respiratory issues, providing a healthier indoor environment.

In terms of user interface, both models are designed with ease of use in mind. They include a remote control that allows users to adjust settings without needing to get up. Additionally, the units have a programmable timer, ensuring that users can set the air conditioning to operate only when needed, enhancing convenience and energy savings.

Another notable technology present in these models is the “Smart Duct” airflow system. This system optimizes air distribution, allowing for an even distribution of cooled air throughout the room. This means fewer hot spots, leading to a more comfortable living or working space.

Both the SAP-KRV93EH and SAP-KRV123EH have sleek designs that blend well with various interior styles, allowing them to fit seamlessly into homes or offices. Furthermore, they operate quietly, ensuring that users can enjoy a peaceful environment.

Overall, the Sanyo SAP-KRV93EH and SAP-KRV123EH air conditioning units combine advanced technology, energy efficiency, and practical features, making them an excellent choice for those looking to enhance their comfort while being conscious of energy usage. With their robust performance and user-friendly attributes, these models epitomize what modern air conditioning solutions should offer.