Agilent Technologies 16440A SMU manual Panel comply with Installation Category

Page 5

Safety Symbols

The general definitions of safety symbols used on equipment or in manuals are listed below.

Instruction manual symbol: the product will be marked with this symbol when it is necessary for the user to refer to the instruction manual in order to protect against damage to the instrument.

Indicates dangerous voltage and potential for electrical shock. Do not touch terminals that have this symbol when instrument is on.

Protective conductor terminal. For protection against electrical shock in case of a fault. Used with field wiring terminals to indicate the terminal which must be connected to ground before operating equipment.

Frame or chassis terminal. A connection to the frame (chassis) of the equipment which normally includes all exposed metal structures.

Indicates earth (ground) terminal.

 

 

 

Alternating current.

 

 

 

Direct current.

 

 

 

 

 

 

ON (Supply).

 

 

 

 

 

 

OFF (Supply).

 

 

 

STANDBY (Supply).

 

CAT 1

Means INSTALLATION CATEGORY I. Measurement terminals on the rear

 

panel comply with INSTALLATION CATEGORY I.

 

 

 

 

 

 

The warning sign denotes a hazard. It calls attention to a procedure, practice,

WARNING

 

 

 

 

 

condition or the like, which, if not correctly performed or adhered to, could result in

 

 

 

injury or death to personal.

 

 

 

 

CAUTION

The caution sign denotes a hazard. It calls attention to an operating procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product.

Agilent 16440A User’s Guide, Edition 4

5

Image 5
Contents Agilent 16440A SMU/Pulse Generator Selector User’s GuideLegal Notice Product WarrantyAssistance Ground the Instrument Panel comply with Installation Category Printing History Users Guide Users Guide Introduction Operation 4155/4156 controls the switching of the selectorUsers Guide Operation All open SMU on PGU on PGU open To Attach the Selector to Test Fixture InstallationFollowing steps apply when using two selectors Users Guide Installation To Attach the Selector to Shielding Box Users Guide Installation Users Guide Installation Users Guide Installation Connecting the Selector to the 4155/4156 PGU Servicing the Selector MaintenanceCleaning the Selector Circuit Block Diagram Replaceable Parts CR1 PGU SpecificationsUsers Guide Specifications Supplemental Information

16440A SMU specifications

Agilent Technologies, now known as Keysight Technologies, offers a range of precision instruments designed for various applications in electronics testing and analysis. One of the standout products in their portfolio is the Agilent 16440A Source Measure Unit (SMU). The Agilent 16440A is tailored for both automated and manual measurements across a broad range of electrical components and systems in research and development, production, and quality assurance.

The Agilent 16440A SMU is a versatile instrument that combines sourcing and measurement capabilities in a single device. This integration allows users to perform tasks such as IV characterization, device testing, and functional testing of semiconductor devices and other electronic components. It can generate precise voltage and current levels while simultaneously measuring the resulting current and voltage, making it ideal for tasks that require high accuracy and reliability.

One of the key features of the Agilent 16440A is its ability to source and measure with high resolution. With a resolution of up to 1 microamp for current and 1 millivolt for voltage, it is well-suited for measuring small signals in highly sensitive devices. Additionally, the SMU includes a wide dynamic range, allowing it to operate effectively across various types of devices, from microelectronic components to larger power devices.

The Agilent 16440A is built on advanced measurement technology that ensures low noise and minimal drift, essential for accurate readings, particularly in precision applications. The unit incorporates a built-in data logging function, enabling users to capture data over time for further analysis. This feature is particularly useful for long-term tests and reliability assessments.

Moreover, the instrument supports a variety of communication interfaces, including USB, GPIB, and Ethernet, facilitating easy integration into automated test systems and enhancing its versatility in different testing environments. Its user-friendly interface ensures that both novice and experienced engineers can operate the SMU efficiently.

In conclusion, the Agilent 16440A SMU stands out for its precision, versatility, and advanced measurement technologies. With features that cater to a wide array of applications, it is an invaluable tool for engineers involved in the testing and characterization of electronic devices. Whether in a laboratory setting or on the production floor, the 16440A delivers reliable performance that meets the demanding needs of modern electronics testing.