Troubleshooting
WARNING
SKIN INJECTION HAZARD
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure
Relief Procedure on page 8.
1.Relieve the pressure.
2.Check all possible causes to the problem before disassembling the pump.
PROBLEM | CAUSE | SOLUTION | |
|
|
| |
Valve does not open | Insufficient air pressure | Turn on or turn up air pressure. | |
|
|
|
|
|
| Air not exhausted from behind air cylin- | Use |
|
| der piston |
|
|
| Shaft adjustment too far closed | Adjust the shaft stroke as instructed on page 9. |
|
|
|
|
Valve | does not close | Insufficient air pressure | Turn on or turn up air pressure. |
(leaks) |
|
|
|
|
| Air not exhausted from behind air cylin- | Use |
|
| der piston |
|
|
| Blockage between needle and seat | Remove and clean needle and seat. |
|
|
|
|
|
| Bad or missing gasket between seat | Replace gasket (38). |
|
| and housing |
|
|
| Needle worn out | Replace needle and seat. |
|
|
|
|
Higher | than normal | Nosepiece plugging up | Remove and clean. |
|
|
10 308876