Graco Inc 243482, 965786, 965767, 243666, 308876, 965768 Air Valve if equipped, Electric Switch

Page 13

Service

(Models 965766, 965767, 965768, and 965786 only)

Air Valve (if equipped)

1.Insert the spring (51) into the housing (50).

2.Lubricate and install an o-ring (46) into the housing.

3.Install a spacer (52), internal bevel first, into the housing.

4.Lubricate and install two o-rings (46) and the spacer (51).

5.Lubricate and install a spacer (52) with the internal bevel out, and o-ring (46).

6.Lubricate and install o-rings (48) on the spool (49). Insert the spool with the nub facing out.

7.Lubricate the pin (59) and insert it into the guide (58). Screw the guide with o-ring (57) into the housing. Tighten it to 60–70 in-lbs (6.8–7.9 NSm).

8.Orient the gasket (30) to the holes on the air cylinder (1). Screw the air valve assembly to the cylinder with the screws (60) and lock-washers (61). TIghten the screws evenly to 15–20 in-lbs (1.7–2.2 NSm).

9.Screw the bushing (53) to the housing (50) with the screw (54). Tighten the screw to 140–150 in-lbs (15.8–16.9 NSm).

10.Attach the handle (55) with the setscrew.

11.Attach the trigger (56) with the grease fittings (18).

12.Test that the trigger safety works properly.

Electric Switch

1.The switch, housing, and cable are not repairable. Replace these parts as a complete assembly.

2.The switch, housing, and cable assembly are not user serviceable and must be replaced as an assembly.

308876 13

Image 13
Contents 1K Ultra-Lite t Instructions-Parts ListSymbols Table of ContentsEquipment Misuse Hazard Fire and Explosion Hazard Features How to Use the Valve Trigger Safety InstallationGrounding Air Switch Hand Held Valve Electric Switch Hand Held ValveConnections Machine Mount ValveElectric Switch Hand Held Valve Pressure Relief ProcedureOperation Machine Mount ValveAir Switch Hand Held Valve MaintenancePreventative Maintenance To adjust the shaft strokeRelief Procedure on Relieve the pressure TroubleshootingDisassembly ServiceModels 965766, 965767, 965768, and 965786 only Air Cylinder Section Models 965766, 965767, 965768, and 965786 only ReassemblyFluid Section Air Valve if equipped Electric Switch28, 29 20 21 22 Models 965766 965768, and 965786 only308876 Parts Automatic Machine Mount Valve ModelDescription Qty Orbiter Mounted ValveOnly Models 243482 and 243666 only Models 243482 and 243666 only Reassembly 28, 29 20 4015 45 2 9 10 30 19 18 16 26 38 28, 29 20 21 Spring Hand Held Valve with Pneumatic TriggerHand Held Valve with Electric Switch Accessories Nozzle Bushing Fluid NozzlesKits Category Data Technical DataDimensions 308876 Graco Information Graco Standard WarrantyToll Free