Graco Inc 243666 Air Switch Hand Held Valve, Preventative Maintenance, To grease the valve

Page 9

Operation

Air Switch Hand Held Valve

The valve operation is such that there are only two valve conditions: either fully open or fully closed.

The valve is opened and closed by the internal air control valve. Trigger the gun to open the valve. Release the trigger to close the valve.

Shaft Stroke Adjustment (Models 965766, 965767, 965768, and 965786 only)

Adjust the shaft stroke to balance the valve between “snuff-back” and “push-out”.

DThe valve is at full stroke when the hex nut

(44)is at the end of the adjustment shaft (42).

DAdjusting the nut (44) on the shaft (42) towards the valve, or clockwise, will reduce the stroke length.

DAdjusting the nut away from the valve, or counterclockwise, will lengthen the stroke.

3.Tighten the hex nut (44) to the adjustment nut (43) to set the adjustment.

42

44

DA long stroke will give maximum snuff-back but it may cause push-out when the valve opens.

DShortening the stroke of the shaft will minimize the material pushed out when the valve opens and will also increase the material back pressure through the valve.

To adjust the shaft stroke:

1.Loosen the hex nut (44) from the adjustment nut (43).

2.Adjust the nut (44) along the adjustment shaft (42) to the desired position.

Shorten

Fig. 4

Lengthen

43

8460

Maintenance

Preventative Maintenance

There is a grease filled secondary seal/bearing area on the valve shaft. Every 10,000 cycles, or twice each month, new grease should be flushed across this area. Each valve has two flush grease fittings. A small grease gun is provided with each valve.

To grease the valve:

1.Remove the grease fitting from one side of the gun.

2.Pump grease (Part No. 115982) across the valve until clear grease comes out of the other side.

3.Reinstall the grease fitting.

308876 9

Image 9
Contents 1K Ultra-Lite t Instructions-Parts ListSymbols Table of ContentsEquipment Misuse Hazard Fire and Explosion Hazard Features Installation How to Use the Valve Trigger SafetyGrounding Air Switch Hand Held Valve Electric Switch Hand Held ValveConnections Machine Mount ValveElectric Switch Hand Held Valve Pressure Relief ProcedureOperation Machine Mount ValveAir Switch Hand Held Valve MaintenancePreventative Maintenance To adjust the shaft strokeRelief Procedure on Relieve the pressure TroubleshootingService DisassemblyModels 965766, 965767, 965768, and 965786 only Models 965766, 965767, 965768, and 965786 only Reassembly Air Cylinder SectionFluid Section Air Valve if equipped Electric Switch28, 29 20 21 22 Models 965766 965768, and 965786 only308876 Parts Automatic Machine Mount Valve ModelDescription Qty Orbiter Mounted ValveOnly Models 243482 and 243666 only Models 243482 and 243666 only Reassembly 28, 29 20 4015 45 2 9 10 30 19 18 16 26 38 28, 29 20 21 Spring Hand Held Valve with Pneumatic TriggerHand Held Valve with Electric Switch Accessories Fluid Nozzles Nozzle BushingKits Category Data Technical DataDimensions 308876 Graco Standard Warranty Graco InformationToll Free