Graco Inc 243666, 308876 Service, Models 965766, 965767, 965768, and 965786 only, Disassembly

Page 11

Service

(Models 965766, 965767, 965768, and 965786 only)

WARNING

SKIN INJECTION HAZARD

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure

Relief Procedure on page 8.

Disassembly

1.Relieve all air and fluid pressure.

2.Disconnect the valve from the system.

3.Remove the four nosepiece screws (15), and pull the nosepiece (40) away from the valve. Remove the snuff-back ring (41). See Fig. 5, page 14.

4.Use an 1/8 in. pin punch in the needle hole (A) to unscrew the needle (27). If the shaft (3) spins, insert a dowel pin in the shaft hole (B) to hold it steady, then unscrew the needle (27).

5.Remove the seat (25), gasket (38), and o-ring (39).

6.Remove the two fluid housing screws (23) and remove the fluid housing (26). Remove the primary fluid seal (22) from the fluid housing (26).

7.Pull the bearing/lube housing (19) from the air cylinder (1). Remove the bearing (21), bearing o-ring (16), and secondary fluid seal (20). Remove the grease fittings (18).

8.Remove the C-clip (12) from the back of the air cylinder (1). Push the shaft (3) into the air cylinder to dislodge the air cylinder cap (11). Remove the cap o-ring.

9.Remove the internal C-clip (12). Push the shaft (3) to dislodge the piston (10) assembly from the air cylinder (1).

10.Remove the adjustment nut (44) from the shaft (3).

11.Remove the adjustment shaft (42) from the shaft

(3).

12.Remove the pin (7), o-ring (9), and piston o-ring

13.Use a 1/4 in. pin punch to knock out the bearings

(5)and o-rings (4).

Air Switch Handle (if equipped)

1.Remove the trigger (56).

2.Loosen the set screw above the trigger safety. Pull off the handle (55).

3.Remove the four retaining screws (60). Pull the housing (50) and gasket (30) away from the air cylinder (1).

Air Valve

1.Unscrew the stem guide (58).

2.Remove the trigger pin (59), o-ring (57), spool (49), spacers (51, 52), o-rings (46, 48) and spring (47).

3.Remove the bushing (53) from the housing (50) with the screw (54).

4.Remove the screws (60) and lock-washers (61) from the air cylinder (1).

Electric Switch Handle (if equipped)

1.Disconnect the power from the gun.

2.The switch, housing, and cable are not repairable. Replace these parts as a complete assembly.

3.Remove the trigger (56).

4.Loosen the setscrew above the trigger safety. Pull off the handle (55).

5.Remove the four manifold retaining screws (60). Pull the housing (50) and gasket (30) away from the air cylinder (1).

6.Remove the bushing (53) from the housing (50) with the screw (54).

7.Remove the screws (60) and lock-washers (61) from the air cylinder (1).

308876 11

Image 11
Contents 1K Ultra-Lite t Instructions-Parts ListSymbols Table of ContentsEquipment Misuse Hazard Fire and Explosion Hazard Features Grounding InstallationHow to Use the Valve Trigger Safety Machine Mount Valve Electric Switch Hand Held ValveAir Switch Hand Held Valve ConnectionsMachine Mount Valve Pressure Relief ProcedureElectric Switch Hand Held Valve OperationTo adjust the shaft stroke MaintenanceAir Switch Hand Held Valve Preventative MaintenanceRelief Procedure on Relieve the pressure TroubleshootingModels 965766, 965767, 965768, and 965786 only ServiceDisassembly Fluid Section Models 965766, 965767, 965768, and 965786 only ReassemblyAir Cylinder Section Air Valve if equipped Electric Switch28, 29 20 21 22 Models 965766 965768, and 965786 only308876 Parts Orbiter Mounted Valve ModelAutomatic Machine Mount Valve Description QtyOnly Models 243482 and 243666 only Models 243482 and 243666 only Reassembly 28, 29 20 4015 45 2 9 10 30 19 18 16 26 38 28, 29 20 21 Spring Hand Held Valve with Pneumatic TriggerHand Held Valve with Electric Switch Accessories Kits Fluid NozzlesNozzle Bushing Category Data Technical DataDimensions 308876 Toll Free Graco Standard WarrantyGraco Information