Outdoor Unit CH1271
Control PCB
Part No.
Controls
Control Circuit Fuse
Compressor
Microprocessor
125V 25A
| Type |
|
| DC Rotary (Inverter) | |
| Compressor Model / Nominal Output |
|
| G4C090LU1ER / 900W | |
| Compressor Oil ... Amount | Pints (cc) | FV50S ... 0.68 (320) | ||
| Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm | U - V : 0.81 | |||
|
|
|
|
| V - W : 0.81 |
|
|
|
|
| W - U : 0.81 |
| Safety Device |
|
| Yes | |
|
| CT (Peak current | |||
|
| Compressor Discharge Temp. Control | Yes | ||
|
| Operation | Yes | ||
|
| Overload Relay |
| Model | |
|
|
| Operation Temp. | Open : 239 °F (115 °C), Close : 203 °F (95 °C) | |
| Run Capacitor |
| Micro F | - | |
|
|
|
| VAC | - |
| Crankcase Heater |
|
| 115V 20W |
Fan
Type |
|
Q'ty ... Dia. | inch (mm) |
Propeller
1 ...
Fan Motor |
|
| ||
| Type |
| DC Motor | |
| Model ... Q'ty |
| ||
| No. of Poles |
| 8 | |
| Rough Measure RPM (Cool / Heat) |
| 750 / 750 | |
| Nominal Output | W | 50 | |
| Coil Resistance | Ohm | RED - WHT : 77.5 | |
| (Ambient Temp. 68 °F (20 °C)) |
| WHT - BLU : 77.5 | |
|
|
|
| BLU - RED : 77.5 |
| Safety Device |
|
| |
|
| Type |
| Internal Controller |
|
| Over- Current Protection |
| Yes |
| Run Capacitor | Micro F | - | |
|
|
| VAC | - |
|
|
|
|
|
Heat Exchanger Coil |
|
| ||
| Coil |
| Aluminum Plate Fin / Copper Tube | |
| Rows |
| 2 | |
| Fins per inch |
| 18.1 | |
| Face Area | ft2 (m2) | 3.95 (0.367) |
External Finish
Acrylic
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
11