Graco 515 Installation, Operation, Moving Parts Hazard, Flush the dispenser before first use

Page 6

Installation

Mounting the Elevator Base to the Floor

WARNING

You must mount the elevator base to the floor before you operate this equipment.

1.Position the elevator where there is at least 9 feet (2.75 meters) of overhead clearance.

2.Mark and drill holes in the floor for 0.5-in. (13 mm) mounting bolts. See the mounting layout in the Dimensional Drawing on page 7.

3.Level the elevator base, using shims if necessary, and bolt the base firmly to the floor.

Grounding

Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, the mounting cover and all electrically conductive objects or devices in the dispensing area must be properly grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment.

To ground the dispenser, connect the end of the ground wire to a true earth ground.

Operation

WARNING

MOVING PARTS HAZARD

To reduce the risk of serious injury, including cuts, amputation of fingers by the agitator blades, and splashing in

the eyes or on the skin, always shut off the agitator (disconnect the air line from the agitator) before you raise, check, or repair the agitator.

Never operate the agitator when the elevator is raised. See Moving Parts Hazard on page 3.

Startup

See the Parts Drawing on page 4.

1.Flush the dispenser before first use.

NOTE: The pump was tested in water. To elimi- nate possible contamination of the fluid you are pumping, before you use the dispenser, flush the pump thoroughly with a solvent compatible to the solvent you are dispensing.

2.Ensure that the needle valve on the agitator is closed and that the dispenser ball valve (19) is closed.

3.Connect the air supply line to the male air line fitting (22).

4.Using the needle valve on the agitator to adjust the agitator speed, gradually increase the speed until you can see (through the inspection port in the drum cover) movement in the surface of the liquid, but do not increase the agitator speed enough to create a vortex in the surface of the liquid. If the surface begins to vortex, decrease the agitator speed to prevent air entrainment.

NOTE: Always maintain moderate agitator speed, which is approximately 50 rpm of the agitator blades. Excessive agitator speed may cause vibration, foaming of fluid, and increased wear on parts. Always agitate fluid thoroughly before supplying it to the dispensing equipment, and continue agitating fluid while the dispensing equip- ment is being supplied.

5.Use the regulator (10) and ball valve (19) to control the pressure and operation of the pump (1).

6.Raise or lower the elevator by pulling out or push- ing in the air control valve (a push-pull handle) on the rim of the drum cover. Normal operation requires only a few seconds for air pressure to build up and raise the elevator or to exhaust and lower the elevator.

NOTE: To increase the operating speed of the elevator, loosen the hex nut on the restrictor valve, and turn the valve needle out. To decrease the operating speed, turn the valve needle in. The restrictor valve is on the top of the elevator, as shown in the Parts Drawing.

6308666

Image 6
Contents 308666 Read and Keep for ReferenceSymbols Equipment Misuse Hazard308666 Fire and Explosion Hazard Moving Parts HazardToxic Fluid Hazard Parts Drawing RestrictorValve Agitator Needle Elevator 11 air control valve Parts List Description QtyMoving Parts Hazard InstallationOperation Flush the dispenser before first useService and Technical Data Dimensional Drawing Graco Warranty and Disclaimers Graco Phone Number

515 specifications

The Graco 515 is a highly regarded airless spray tip designed for use in a variety of painting applications, making it a popular choice among contractors and DIY enthusiasts. Known for its durability and versatility, the Graco 515 is engineered to deliver a smooth and even finish on a range of surfaces, including walls, ceilings, and large exterior areas.

One of the standout features of the Graco 515 is its 0.015-inch orifice size, which caters to a variety of coatings. This makes it suitable for spraying a wide range of materials, from thick latex paints to thinner stains and finishes. The tip is capable of producing a fan width of approximately 10 to 12 inches, allowing for efficient coverage and reducing the time needed to complete a job.

The Graco 515 incorporates several advanced technologies that enhance its performance. One major innovation is the use of a hardened stainless steel construction that not only provides longevity but also resists corrosion and wear, making it ideal for use in different environments and conditions. The tip is designed to withstand the rigors of professional use while maintaining precision in spraying.

Another notable characteristic is the Reverse-A-Clean (RAC) feature. This allows the user to quickly clear clogs by simply twisting the tip, which reverses the flow and enables blockage removal without the need for extensive downtime. This functionality is particularly beneficial for those working on large projects where time efficiency is crucial.

Moreover, the Graco 515 is compatible with a wide range of Graco spray guns, making it a versatile addition to any painting kit. Its ease of attachment and detachability simplifies the process of switching between different spray tips depending on the needs of the project.

In conclusion, the Graco 515 airless spray tip combines efficiency, durability, and user-friendly features, making it an indispensable tool for anyone looking to achieve professional-quality finishes. Whether for residential or commercial use, the Graco 515 delivers outstanding performance that can help streamline the painting process and enhance overall results.