LED DISPLAY

The LED readouts identify the current status of the PID-750.

VOLTAGE IN: Voltage of vehicle’s battery or Portable Power jump starter/DC power source.

VOLTAGE OUT: Voltage supplied to device through AC receptacle.

POWER OUT: Power or wattage supplied to device plugged into the inverter.

An audio alarm will sound when the following codes display. To stop the alarm, press the ON/OFF LED Selector button:

BaD – Inverter is not functional. See warranty and call Customer Service 800-621-5485 (Hours: 7 a.m. – 4:30 p.m. CST).

Hi b – Vehicle’s battery voltage is more than 15.5 volts. Inverter will automatically restart after the voltage drops below 15.0 volts.

HiP – The continuous load demand from the device exceeds 750 watts.

HoT – Inverter is overheated and automatically turns off for a period of 1–3 minutes to cool. Make sure inverter is well ventilated. It will automatically restart after it cools.

Lob – Vehicle’s battery voltage is less than 10.5 volts.

SC – Short circuit, power surge or overload in the device.

7

Image 8
Contents Includes Battery Cables Page Important Safety Instructions Before Using PID-750 power Inverter Wash hands after handlingConnecting to a 12 Volt Battery Operating instructionsPower Source Usage Examples Device Type Estimated WattageLED Display Troubleshooting Problem Alarm is OnProblem Inverter Does Not Turn On Specifications Limited Warranty Page Manual DEL Dueño Page Guarde Estas Instrucciones Instrucciones Importantes DE SeguridadLas manos después de manejarlo Antes de Usar el Inversor PID-750Instrucciones DE Operación Para conectar a una batería de 12 voltiosFuente DE Potencia Tipo de Dispositivo Vataje Estimado Ejemplos DE UsosLecturas POR LED Solución DE Problemas Problema El Inversor no se Enciende. Causa/SoluciónPage Problema El Inversor No se Enciende. Causa/Solución Especificaciones Garantía Limitada Page Notas