TROUBLESHOOTING

PROBLEM: Alarm is On

Reason/Solution

1.Display shows SC. Device has a short circuit or de- mands too much surge power.

Cycle inverter power OFF and ON.

If problem persists, use a larger inverter or a smaller device.

Remove defective device.

See warranty and call Customer Service

800-621-5485 (Hours: 7 a.m. – 4:30 p.m. CST).

2.Display shows Lob. 12 Volt battery too low. Recharge/replace low battery.

3.Display shows Voltage In between 10.5 and 11.0 Volts.

12 Volt battery is low. Recharge/replace low battery.

Inverter will automatically shut off after battery volt- age reaches 10.5 volts.

4.Display shows Hi b. 12 Volt voltage is too high. If in a vehicle, repair/replace the alternator or charging system.

Use a properly sized and rated 12 Volt battery.

If input voltage returns to 15 volts or less, the in- verter will automatically restart.

8

Image 9
Contents Includes Battery Cables Page Important Safety Instructions Wash hands after handling Before Using PID-750 power InverterOperating instructions Connecting to a 12 Volt BatteryPower Source Device Type Estimated Wattage Usage ExamplesLED Display Problem Alarm is On TroubleshootingProblem Inverter Does Not Turn On Specifications Limited Warranty Page Manual DEL Dueño Page Instrucciones Importantes DE Seguridad Guarde Estas InstruccionesAntes de Usar el Inversor PID-750 Las manos después de manejarloPara conectar a una batería de 12 voltios Instrucciones DE OperaciónFuente DE Potencia Ejemplos DE Usos Tipo de Dispositivo Vataje EstimadoLecturas POR LED Problema El Inversor no se Enciende. Causa/Solución Solución DE ProblemasPage Problema El Inversor No se Enciende. Causa/Solución Especificaciones Garantía Limitada Page Notas