Porter-Cable 902387 To Change HEX Nutsetter Models 6641, To Adjust Depth Stop Models 6641

Page 6

902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 6

1.Make sure power circuit voltage is the same as that shown on the specification plate of screwdriver. Connect screwdriver to power circuit.

2.Squeeze trigger switch (A), Fig. 1, to start motor, as the trigger switch is squeezed, the driver speed increases. The screwdriver bit will not rotate until engaged in a fastener and forward pressure is applied to the tool. To stop motor, release trigger switch.

3.LOCK BUTTON - A lock button (B), Fig. 1, is provided to keep motor running without holding the trigger switch ON.

TO LOCK the trigger switch ON, squeeze the trigger as far as it will go, push in lock button and release trigger.

TO UNLOCK lock button, squeeze trigger and release, leaving lock button free to spring out.

4.DIRECTION OF ROTATION – PORTER-CABLE screwdrivers will rotate either in a clockwise direction for driving fasteners with a right hand thread, or a counter clockwise direction for removing fasteners with a right hand thread. To determine rotation, stop the motor by releasing the trigger switch and move the reversing lever (C), Fig. 1, in the direction marked “reverse” for counter- clockwise rotation, or in the opposite direction for clockwise rotation.

C

A

B

Fig. 1

TO CHANGE HEX NUTSETTER – MODELS 6641, 6642

1.CAUTION: DISCONNECT TOOL FROM POWER SOURCE.

2.Pull the adjusting collar (A), Fig. 2, forward, (away from the power unit), and rotate collar counterclockwise, to remove the depth stop assembly (B), Fig. 2, from the clutch housing.

3.Pull nutsetter (C), Fig. 3, straight out. If it is difficult to remove, grip with pliers and pull.

4.Push selected nutsetter into screwdriver spindle until ball in spindle snaps into groove in nutsetter shank.

5.Replace depth stop and adjust for depth of drive (see TO ADJUST DEPTH STOP, MODELS 6641, 6642).

TO ADJUST DEPTH STOP – MODELS 6641, 6642

1.Pull the adjusting collar (A), Fig. 2, forward, (away from power unit), and hold while performing step 2.

2.Turn adjusting collar until end of depth stop is flush with end of nutsetter. Do not push in nutsetter as this will engage internal drive.

6

Image 6
Contents Español Página Française Personal Safety General Safety RulesElectrical Safety Work AreaService Tools USE and CareSpecific Safety Rules and Symbols for Screwdrivers Replacement PartsExtension Cord Selection Functional DescriptionMotor ForewordTo Adjust Depth Stop Models 6641 To Change HEX Nutsetter Models 6641ABD Driving Drywall Screws Models 6640 To Adjust Depth Stop Models 6640To Change BIT Holder Models 6640 Driving SELF-DRILLING/TAPPING Screws Models 6640To Remove Screws ALL Models MaintenanceKeep Tool Clean Failure to StartService and Repairs Brush Inspection and LubricationAccessories PORTER-CABLE Limited ONE Year Warranty Canadian PORTER-CABLE Delta Service Centers