Unit Display and Operation Selector

INDOOR UNIT

KS1852

ON

OFF

TEST

Operation selector

OPERATION lamp TIMER lamp Remote control

 

 

 

receiver

 

 

 

 

OPERATION

TIMER

 

 

 

 

 

 

 

 

 

IMPORTANT

Avoid using radio equipment such as mobile phones near (within 4 ft. of) the indoor unit. Some radio equipment may cause the unit to malfunction.

If the trouble occurs, disconnect power and restart the air conditioner after a few minutes.

INDOOR UNIT

Operation selector

KS0951

 

KS1251

 

 

ON

 

OFF

 

TEST

Remote control receiver

OPERATION

TIMER

TIMER lamp

OPERATION lamp

 

Remote control receiver

This section picks up infrared signals from the remote control unit

 

 

 

 

(transmitter).

 

 

 

 

 

 

Operation selector

 

 

 

ON position

This position is for operating the air conditioner with the wireless

 

 

 

 

remote control unit.

 

 

 

 

Set the selector normally in this position.

 

 

 

 

 

 

OFF position

Switch the selector to the OFF position if you are not going to use

 

 

 

 

the air conditioner for a few days or longer.

 

 

 

 

The OFF position does not disconnect the power. Use the main

 

 

 

 

power switch to turn off power completely.

 

 

 

 

 

 

TEST position

This position is used only when servicing the air conditioner.

 

 

 

 

Do not set the operation selector at the TEST position for normal

 

 

CAUTION

 

 

 

 

operation.

 

 

 

 

 

 

 

 

 

 

OPERATION lamp

This lamp lights when the system is in the continuous DRY and

 

 

 

 

COOL mode.

 

 

 

 

 

 

 

TIMER lamp

This lamp lights when the system is being controlled by the timer.

 

 

 

 

 

6

OI-330-06EG

Image 6
Contents KS0951 KS1251 KS1852 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit Operation selector Remote control receiverKS1852 KS0951 KS12511HR Remote Control Unit Hour OFF Timer DRYCool Using the Remote Control Unit How to Install BatteriesDo not When using the remote control unit Using the Remote Control UnitMounting the Remote Control Unit Securing the remote control unit to prevent theftStep Operation with the Remote Control UnitManual Operation StepOperation with the Remote Control Unit Adjusting the Fan SpeedFAN Speed Night Setback Mode Night SetbackSpecial Remarks Power failure during operation Clicking SoundRemote Control Unit ``DRY OperationSetting theTimer How to set the present timeOperation Indication Setting the Timer How to set a program for daily ON/OFF operationSetting procedure Setting the 1-Hour OFFTimerHour OFF Timer Operation Together with the Program Timer Cancellation procedureAdjusting the Airflow Direction HorizontalOperation Operation without the Remote Control UnitCare and Cleaning KS1852 SelectorHow to replace the anti-mold filter Care and CleaningAnti-mold filter How to remove the anti-mold filter Air intake grilleAir cleaning filter not provided KS0951/KS1251Tips for Energy Saving Do notRemoving and remounting Sanyo Fisher Company TroubleshootingOperating Range Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 29.34 Kb

KS1251, KS0951 specifications

The Sanyo KS0951 and KS1251 are two formidable air conditioning units designed to deliver optimal cooling performance while ensuring energy efficiency. Sanyo, renowned for its innovative technologies, has incorporated a range of advanced features into these models, making them suitable for both residential and commercial applications.

One of the key features of the Sanyo KS0951 and KS1251 is their high energy efficiency rating. Both models utilize advanced inverter technology, which allows the units to adjust their compressor speed according to the cooling demands. This variable speed operation not only provides consistent temperature control but also reduces energy consumption significantly, leading to lower electricity bills.

The cooling capacity of the KS0951 is approximately 9000 BTUs, while the KS1251 boasts a capacity of around 12000 BTUs. This makes them ideal for medium-sized to larger rooms, offering effective cooling even in hot weather conditions. With efficient airflow distribution, these units ensure that every corner of the room receives adequate cooling.

Another notable characteristic of the Sanyo KS series is the implementation of advanced air filtration systems. Equipped with multi-stage filters, these units effectively remove dust, allergens, and other airborne particles, promoting a healthier indoor environment. The filters are easy to access and clean, ensuring that maintenance is hassle-free and air quality remains high.

Noise reduction technology is another significant feature of the KS0951 and KS1251. Both models operate at low noise levels, providing a peaceful environment, whether it’s at home or in an office setting. This acoustic comfort is further enhanced by the use of sound-dampening materials and advanced compressor designs.

User-friendly features also set these models apart. The inclusion of remote control functionality allows users to adjust settings conveniently from anywhere in the room. Additionally, programmable timers and multiple cooling modes provide flexibility according to various needs and preferences.

In conclusion, the Sanyo KS0951 and KS1251 are standout air conditioning units that combine efficient cooling performance with user-friendly features and advanced technology. Their ability to provide a comfortable and healthy indoor environment, coupled with energy efficiency, makes them a wise choice for consumers seeking reliability and innovation in climate control solutions. Whether for home or office use, these models exemplify Sanyo's commitment to quality and customer satisfaction.