1. Manual Operation

STEP 2

STEP 3

STEP 1

STEP 4

STEP 5

NOTE

Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position.

Press the setting buttons as described below and change the settings as desired.

 

STEP 1

 

Press the MODE selector button and select the desired

 

 

 

mode.

 

 

 

For drying operation

 

 

 

For cooling operation

 

STEP 2

 

To start the air conditioner, press the ON/OFF

 

 

 

operation button.

 

 

 

 

 

 

STEP 3

 

Press the temperature setting buttons to change the

 

 

 

temperature setting to the desired temperature.

 

 

 

Adjustable temperature range:

 

 

 

 

86 °F max.

 

 

 

 

60 °F min.

 

 

 

The temperature setting changes by two degrees each

 

NOTE

 

 

time the button is pressed. (The air conditioner

 

 

 

 

 

 

remembers the new temperature setting even when it is

 

 

 

turned off.)

 

 

 

 

 

 

STEP 4

 

Set the FAN SPEED selector button to the setting you want.

 

 

 

If the fan speed is set to

(Automatic), the fan speed

 

NOTE

 

 

 

switches automatically, according to the difference

 

 

 

 

 

between the actual room temperature and the temperature

 

 

 

setting.

 

 

 

 

 

 

STEP 5

 

Press the FLAP button and set the airflow direction as

 

 

 

desired.

 

 

 

 

(Refer to ˝Adjusting the Airflow Direction˝ on page 19.)

 

 

 

 

 

To stop the air conditioner, press the ON/OFF operation button again.

12

OI-330-12EG

Image 12
Contents KS0951 KS1251 KS1852 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit Remote control receiver KS1852Operation selector KS0951 KS12511HR Remote Control Unit Hour OFF Timer DRYCool Using the Remote Control Unit How to Install BatteriesDo not Using the Remote Control Unit Mounting the Remote Control UnitWhen using the remote control unit Securing the remote control unit to prevent theftOperation with the Remote Control Unit Manual OperationStep StepOperation with the Remote Control Unit Adjusting the Fan SpeedFAN Speed Night Setback Mode Night SetbackPower failure during operation Clicking Sound Remote Control UnitSpecial Remarks ``DRY OperationSetting theTimer How to set the present timeOperation Indication Setting the Timer How to set a program for daily ON/OFF operationSetting the 1-Hour OFFTimer Hour OFF Timer Operation Together with the Program TimerSetting procedure Cancellation procedureAdjusting the Airflow Direction HorizontalOperation without the Remote Control Unit Care and CleaningOperation KS1852 SelectorCare and Cleaning Anti-mold filter How to remove the anti-mold filterHow to replace the anti-mold filter Air intake grilleAir cleaning filter not provided KS0951/KS1251Tips for Energy Saving Do notRemoving and remounting Troubleshooting Operating RangeSanyo Fisher Company Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 29.34 Kb

KS1251, KS0951 specifications

The Sanyo KS0951 and KS1251 are two formidable air conditioning units designed to deliver optimal cooling performance while ensuring energy efficiency. Sanyo, renowned for its innovative technologies, has incorporated a range of advanced features into these models, making them suitable for both residential and commercial applications.

One of the key features of the Sanyo KS0951 and KS1251 is their high energy efficiency rating. Both models utilize advanced inverter technology, which allows the units to adjust their compressor speed according to the cooling demands. This variable speed operation not only provides consistent temperature control but also reduces energy consumption significantly, leading to lower electricity bills.

The cooling capacity of the KS0951 is approximately 9000 BTUs, while the KS1251 boasts a capacity of around 12000 BTUs. This makes them ideal for medium-sized to larger rooms, offering effective cooling even in hot weather conditions. With efficient airflow distribution, these units ensure that every corner of the room receives adequate cooling.

Another notable characteristic of the Sanyo KS series is the implementation of advanced air filtration systems. Equipped with multi-stage filters, these units effectively remove dust, allergens, and other airborne particles, promoting a healthier indoor environment. The filters are easy to access and clean, ensuring that maintenance is hassle-free and air quality remains high.

Noise reduction technology is another significant feature of the KS0951 and KS1251. Both models operate at low noise levels, providing a peaceful environment, whether it’s at home or in an office setting. This acoustic comfort is further enhanced by the use of sound-dampening materials and advanced compressor designs.

User-friendly features also set these models apart. The inclusion of remote control functionality allows users to adjust settings conveniently from anywhere in the room. Additionally, programmable timers and multiple cooling modes provide flexibility according to various needs and preferences.

In conclusion, the Sanyo KS0951 and KS1251 are standout air conditioning units that combine efficient cooling performance with user-friendly features and advanced technology. Their ability to provide a comfortable and healthy indoor environment, coupled with energy efficiency, makes them a wise choice for consumers seeking reliability and innovation in climate control solutions. Whether for home or office use, these models exemplify Sanyo's commitment to quality and customer satisfaction.