Sanyo KS1251 Special Remarks, ``DRY Operation, Power failure during operation Clicking Sound

Page 15

Special Remarks

``DRY'' ( ) Operation

How it works?

Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically.

During DRY operation, the fan speed is automatically set to LOW or VERY LOW; the fan speed then switches back and forth between LOW (for 20 seconds) and VERY LOW (for 10 seconds).

“DRY” operation is not possible if the indoor temperature is 59 °F or less.

Power failure during operation

Clicking Sound

Clicking sound is heard from the air conditioner

Remote Control Unit

IMPORTANT

In the event of power failure, the unit will stop. When the power is turned on again, the unit restarts within five minutes.

In cooling and drying operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear.

The remote control unit sends the setting condition to the air conditioner regularly at five minute intervals.

KS1852 and CL1852 Combination

When this unit is combined with the CL1852 outdoor unit, set the indoor airflow to medium or high when the outdoor temperature drops below 32 °F to prevent condensation from forming at the indoor unit.

OI-330-15EG

15

Image 15
Contents KS0951 KS1251 KS1852 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit KS0951 KS1251 Remote control receiverKS1852 Operation selector1HR Remote Control Unit Hour OFF Timer DRYCool Using the Remote Control Unit How to Install BatteriesDo not Securing the remote control unit to prevent theft Using the Remote Control UnitMounting the Remote Control Unit When using the remote control unitStep Operation with the Remote Control UnitManual Operation StepOperation with the Remote Control Unit Adjusting the Fan SpeedFAN Speed Night Setback Night Setback Mode``DRY Operation Power failure during operation Clicking SoundRemote Control Unit Special RemarksSetting theTimer How to set the present timeOperation Indication How to set a program for daily ON/OFF operation Setting the TimerCancellation procedure Setting the 1-Hour OFFTimerHour OFF Timer Operation Together with the Program Timer Setting procedureHorizontal Adjusting the Airflow DirectionKS1852 Selector Operation without the Remote Control UnitCare and Cleaning OperationAir intake grille Care and CleaningAnti-mold filter How to remove the anti-mold filter How to replace the anti-mold filterKS0951/KS1251 Air cleaning filter not providedTips for Energy Saving Do notRemoving and remounting Division of Sanyo North America Corporation TroubleshootingOperating Range Sanyo Fisher Company
Related manuals
Manual 24 pages 29.34 Kb

KS1251, KS0951 specifications

The Sanyo KS0951 and KS1251 are two formidable air conditioning units designed to deliver optimal cooling performance while ensuring energy efficiency. Sanyo, renowned for its innovative technologies, has incorporated a range of advanced features into these models, making them suitable for both residential and commercial applications.

One of the key features of the Sanyo KS0951 and KS1251 is their high energy efficiency rating. Both models utilize advanced inverter technology, which allows the units to adjust their compressor speed according to the cooling demands. This variable speed operation not only provides consistent temperature control but also reduces energy consumption significantly, leading to lower electricity bills.

The cooling capacity of the KS0951 is approximately 9000 BTUs, while the KS1251 boasts a capacity of around 12000 BTUs. This makes them ideal for medium-sized to larger rooms, offering effective cooling even in hot weather conditions. With efficient airflow distribution, these units ensure that every corner of the room receives adequate cooling.

Another notable characteristic of the Sanyo KS series is the implementation of advanced air filtration systems. Equipped with multi-stage filters, these units effectively remove dust, allergens, and other airborne particles, promoting a healthier indoor environment. The filters are easy to access and clean, ensuring that maintenance is hassle-free and air quality remains high.

Noise reduction technology is another significant feature of the KS0951 and KS1251. Both models operate at low noise levels, providing a peaceful environment, whether it’s at home or in an office setting. This acoustic comfort is further enhanced by the use of sound-dampening materials and advanced compressor designs.

User-friendly features also set these models apart. The inclusion of remote control functionality allows users to adjust settings conveniently from anywhere in the room. Additionally, programmable timers and multiple cooling modes provide flexibility according to various needs and preferences.

In conclusion, the Sanyo KS0951 and KS1251 are standout air conditioning units that combine efficient cooling performance with user-friendly features and advanced technology. Their ability to provide a comfortable and healthy indoor environment, coupled with energy efficiency, makes them a wise choice for consumers seeking reliability and innovation in climate control solutions. Whether for home or office use, these models exemplify Sanyo's commitment to quality and customer satisfaction.