Troubleshooting Guide

Possible Trouble 6

Remote controller does not operate.

 

 

Is the voltage of Battery

NO

over 2.3V?

 

 

YES

 

 

 

Is the voltage No.10

NO

of CN-AC/DC on DC PCB

 

Ass'y DC 5V?

 

 

YES

 

 

 

Is the connection of

NO

CN-AC/DC OK?

 

YES

• Replace Receiver Ass'y.

• Replace the battery.

Check the PCB pattern.

Check the PCB pattern.

Connect connector to CN-AC/DC exactly.

Possible Trouble 7

Is IC01G good?

YES

It displays abnormally on DC PCB Ass’y.

NO

NO

• Replace IC01G.

Is the connection of

NO

CN-AC/DC OK?

 

 

YES

 

 

 

Does the IC03G

NO

(Q01G, Q02G, Q03G for Delux Model)

operate normally on DC

 

PCB Ass'y?

 

 

YES

 

 

 

Replace the DC PCB Ass'y.

• Connect connector to CN-AC/DC exactly.

• Replace IC03G (Q01G, Q02G, Q03G for Delux Model).

Service Manual 29

Page 29
Image 29
LG Electronics M8004RY4, L8004RY4, HB8004RA4, HB8004RB4, M1004R, HB1004R Possible Trouble Remote controller does not operate