Troubleshooting Guide

Electrical Parts

Possible Trouble 1

The unit does not operate.

Is the

Trans input power AC 115V?

YES

Is the Trans output power

about AC 14V?

YES

Is output Voltage of IC01D

DC 12V?

YES

Is output Voltage of IC02D

DC 5V?

YES

Is the reset circuit OK?

(The No.14 of Micom is 5V.)

YES

Is the connection between

AC and DC

OK?

YES

NO

 

• Check the Fuse.

 

 

 

 

 

 

• Check the Fuse.

 

 

 

 

• Check the wiring diagram.

 

 

 

 

• Check the wiring diagram.

 

 

 

 

 

 

NO

Is shorted the Trans. output?

NO

 

 

• Check the AC

 

 

 

 

 

 

 

 

 

PCB pattern.

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Replace the Trans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

• Replace D02D~D05D.

 

 

 

 

 

 

 

• Replace IC01D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

• Replace IC02D.

 

NO

• Replace IC01A, C01A.

 

NO

 

• Connect connector

 

 

 

 

 

 

exactly.

 

 

 

 

 

 

 

 

 

 

 

Is the voltage No.40 of Micom

NO

 

• Check the PCB

 

 

 

 

 

 

pattern.

 

DC 5V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Replace AC PCB Ass'y.

30Room Air Conditioner

Page 30
Image 30
LG Electronics L8004RY4, HB8004RA4, HB8004RB4, M1004R, M8004RY4, HB1004R service manual Is the reset circuit OK?