LG Electronics M1004R, L8004RY4, HB8004RA4, HB8004RB4, M8004R Possible Trouble FAN does not operate

Models: HB8004RB4 HB8004R HB1004R HB8004RA4 M8004RY4 L8004RY4 M8004R M1004R

1 40
Download 40 pages 59.54 Kb
Page 28
Image 28

Troubleshooting Guide

Possible Trouble 4

FAN does not operate.

 

 

Is the voltage NO.1 or 2 or 4

NO

 

of IC01M DC 12V?

 

 

YES

 

 

 

Is the voltage NO.16 or 15 or 13

NO

 

of IC01M 0V?

 

YES

Check the RY-Hi or RY-Med or RY-Lo.

Check the wiring diagram.

Replace IC01M.

Replace IC01M.

Possible Trouble 5

The function of Energy Saver does not operate.

 

 

Is the mode

NO

key pushed once more from

 

 

cool mode?

 

 

YES

 

 

 

Is the voltage No.3 of

NO

CN-AC/DC of AC PCB

 

Ass'y DC 5V?

 

YES

Reference to

OWNER'S MANUAL.

Set the mode key to Energy Saver mode.

Check the Energy Saver mode key.

Check the pattern of AC & DC PCB.

28Room Air Conditioner

Page 28
Image 28
LG Electronics M1004R Possible Trouble FAN does not operate, Possible Trouble Function of Energy Saver does not operate