Sanyo KS1251, KS0951 instruction manual Dry, Cool, Hour OFF Timer

Page 9

 

 

Remote Control Unit (continued)

 

 

 

 

 

 

 

 

 

Program button

For details, see “Setting theTimer”.

 

 

Press this button to select the mode you want to program.

 

 

 

 

 

 

 

 

 

TIMER SELECT button

No display : The timer does not operate.

 

 

 

 

 

: The air conditioner stops at the set time.

 

 

 

 

 

 

 

 

 

: The air conditioner starts at the set time.

 

 

 

 

 

: The air conditioner stops and starts, or starts and stops, at the

 

 

 

 

 

 

set times every day.

 

 

 

 

 

 

 

 

 

MODE selector button

Use this button to select the DRY or COOL mode.

 

(DRY)

 

 

 

: The air conditioner reduces the humidity in the room.

(COOL)

 

 

 

: The air conditioner makes the room cooler.

 

 

 

 

 

 

 

 

 

FLAP button

Press this button either to select to set the airflow direction to one of the six

 

 

possible positions manually, or to select the sweep function, which moves

 

 

the flap up and down automatically.

 

 

 

 

 

: The airflow direction can be set manually. (six positions)

 

 

 

 

 

: The flap moves up and down automatically.

 

 

When you press the FLAP button, the air flow direction will be changed one

 

NOTE

 

 

by one as follows.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Swing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN SPEED selector button

 

 

 

: The air conditioner automatically decides the fan speeds.

 

 

 

 

 

: High fan speed

 

 

 

 

 

: Medium fan speed

 

 

 

 

 

: Low fan speed

 

 

 

 

 

 

 

 

 

 

1 HR. TIMER button

 

 

 

: When you press this button, regardless of whether the unit is

(1-HOUR OFF TIMER)

 

 

 

operating or stopping, the unit operates for one hour and then

 

 

 

 

 

shuts down.

 

ACL button (ALL CLEAR)

Puts the remote control unit into pre-operation status. Always press this

 

 

button after replacing the batteries.

 

 

 

 

 

 

 

 

 

ADDRESS switch

Change the address switch to prevent mixing of signals from remote control

 

 

 

units when two Sanyo air conditioners are installed next to each other.

 

 

 

Normally, the address switch is set to A. When switching the address, the

 

 

 

remote control must be changed, and the jumper cables on the indoor unit

 

 

 

board must be cut. For more information, please contact the dealer where

 

 

 

you made the purchase.

Normally, the tabs on the remote control unit should not be bent.

SENSOR button When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly.

NOTE If the remote control is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

NOTE

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

OI-330-9EG

9

Image 9
Contents KS0951 KS1251 KS1852 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit KS1852 Remote control receiverOperation selector KS0951 KS12511HR Remote Control Unit Hour OFF Timer DRYCool Using the Remote Control Unit How to Install BatteriesDo not Mounting the Remote Control Unit Using the Remote Control UnitWhen using the remote control unit Securing the remote control unit to prevent theftManual Operation Operation with the Remote Control UnitStep StepOperation with the Remote Control Unit Adjusting the Fan SpeedFAN Speed Night Setback Night Setback ModeRemote Control Unit Power failure during operation Clicking SoundSpecial Remarks ``DRY OperationSetting theTimer How to set the present timeOperation Indication How to set a program for daily ON/OFF operation Setting the TimerHour OFF Timer Operation Together with the Program Timer Setting the 1-Hour OFFTimerSetting procedure Cancellation procedureHorizontal Adjusting the Airflow DirectionCare and Cleaning Operation without the Remote Control UnitOperation KS1852 SelectorAnti-mold filter How to remove the anti-mold filter Care and CleaningHow to replace the anti-mold filter Air intake grilleKS0951/KS1251 Air cleaning filter not providedTips for Energy Saving Do notRemoving and remounting Operating Range TroubleshootingSanyo Fisher Company Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 29.34 Kb

KS1251, KS0951 specifications

The Sanyo KS0951 and KS1251 are two formidable air conditioning units designed to deliver optimal cooling performance while ensuring energy efficiency. Sanyo, renowned for its innovative technologies, has incorporated a range of advanced features into these models, making them suitable for both residential and commercial applications.

One of the key features of the Sanyo KS0951 and KS1251 is their high energy efficiency rating. Both models utilize advanced inverter technology, which allows the units to adjust their compressor speed according to the cooling demands. This variable speed operation not only provides consistent temperature control but also reduces energy consumption significantly, leading to lower electricity bills.

The cooling capacity of the KS0951 is approximately 9000 BTUs, while the KS1251 boasts a capacity of around 12000 BTUs. This makes them ideal for medium-sized to larger rooms, offering effective cooling even in hot weather conditions. With efficient airflow distribution, these units ensure that every corner of the room receives adequate cooling.

Another notable characteristic of the Sanyo KS series is the implementation of advanced air filtration systems. Equipped with multi-stage filters, these units effectively remove dust, allergens, and other airborne particles, promoting a healthier indoor environment. The filters are easy to access and clean, ensuring that maintenance is hassle-free and air quality remains high.

Noise reduction technology is another significant feature of the KS0951 and KS1251. Both models operate at low noise levels, providing a peaceful environment, whether it’s at home or in an office setting. This acoustic comfort is further enhanced by the use of sound-dampening materials and advanced compressor designs.

User-friendly features also set these models apart. The inclusion of remote control functionality allows users to adjust settings conveniently from anywhere in the room. Additionally, programmable timers and multiple cooling modes provide flexibility according to various needs and preferences.

In conclusion, the Sanyo KS0951 and KS1251 are standout air conditioning units that combine efficient cooling performance with user-friendly features and advanced technology. Their ability to provide a comfortable and healthy indoor environment, coupled with energy efficiency, makes them a wise choice for consumers seeking reliability and innovation in climate control solutions. Whether for home or office use, these models exemplify Sanyo's commitment to quality and customer satisfaction.