Panasonic EY3551-U1, EY3552-U1 specifications Ref. No B Procedure 2A → 2B Removal of the shoe

Page 5

EY3551-U1 / EY3552-U1

Ref. No. 2B

Procedure 2A 2B

Removal of the shoe.

 

 

NOTE:

 

 

 

It is possible to disassemble the main unit without removing the

 

 

 

shoe.

 

 

1.

Take out the E-ring and the depth adjustment lever.

 

 

2.

Unscrew the hex nut.

 

 

3.

Take out the spring washer and piling catahats washer.

 

 

4.

Pull out the square screw and pipe.

 

 

5.

Take out the stopper washer and toothed lock washer.

 

 

6.

Push out the spring pin with a rod having a diameter of 5mm.

 

 

NOTE:

Do not tap the spring pin strongly. If to do so, the supporting metal plates on both side of housing may cause the deformation.

Ref. No. 2C

Procedure 2A 2C

Removal of the Housing.

1. Loosen 7 housing screws (frearson type) and 1 (+) head screw. It is then possible to disassembly the main unit or to check the switch block and motor.

5

Image 5
Contents EY3551-U1 EY3552-U1 EY3551 EY3551 EY3552 Ref. No a Procedure 1A Blade removalLoosen the base depth adjustment lever where located under Ref. No C Procedure 2A → 2C Removal of the Housing Ref. No B Procedure 2A → 2B Removal of the shoeTake out the motor rotor assembly from the motor stator Ref. No a Procedure 3A Assembly of the motor assembly Assembly InstructionsRef. No C Procedure 3A → 3B → 3C Assembly of the switch Tighten the 7 frearson housing screws and 1 + head screw EY3551-U1 / EY3552-U1 EY3551-U1 / EY3552-U1 Refer to Wiring Connection Diagram EY3551-U1 / EY3552-U1 Exploded View & Replacement Parts List Replacement Parts List for EY3551 Exploded View for EY3552 Replacement Parts List for EY3552