3.Charging

When the battery is connected to the battery charger, charging will commence and the pilot lamp will light in red. (See Table 2)

NOTE: If the pilot lamp does not light, pull out the plug from the receptacle and check if the battery is properly mounted.

When the battery is fully charged, the pilot lamp will blink in red slowly. (At 1-second intervals) (See Table 2)

(1)Pilot lamp indication

The indications of the pilot lamp will be as shown in Table 2, according to the condition of the charger or the rechargeable battery.

 

 

 

 

Table 2

 

 

 

 

 

 

 

 

 

 

 

 

Indications of the pilot lamp

 

Before

Blinks

Lights for 0.5 seconds. Does not light for

 

charging

(RED)

0.5 seconds. (off for 0.5 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

While

Lights

Lights continuously

 

charging

(RED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charging

Blinks

Lights for 0.5 seconds. Does not light for

 

completed

(RED)

0.5 seconds. (off for 0.5 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charging

Flickers

Lights for 0.1 seconds. Does not light for

Malfunction in the

impossible

(RED)

0.1 seconds. (off for 0.1 seconds)

battery or the charger

 

 

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

 

 

 

 

 

 

 

 

 

 

Charging

Lights

Lights continuously

The battery temperature

impossible

(GREEN)

 

 

 

 

 

 

is high, making recharg-

 

 

 

 

 

 

 

 

 

 

 

 

(UC14YF / UC14YF2 only)

 

 

 

 

 

 

ing impossible.

(2)Regarding the temperature of the rechargeable battery.

The temperatures for rechargeable batteries are as shown in the table below, and batteries that have become hot should be cooled for a while before being recharged.

Table 3 Recharging of batteries that have become hot

Rechargeable batteries

Temperatures at which the battery can be recharged

EB 9

23°F—104°F (–5°C—40°C)

EB 9B

23°F—140°F (–5°C—60°C)

15

Image 15 Contents
Safety Instructions For Cordless Angle Drill Contents Important Information Meanings of Signal WordsSafety Keep Children Away Handle Tool Correctly Important Safety Instructions for Battery Charger Follow these instructions to avoid the risk of injury Disposal of the Exhausted Battery Cordless Angel Drill DN10DY Battery EB9, EB9BModel Name of Parts Specifications Battery Charger Cordless Angle Drill DN10DY Standard Accessories AccessoriesWood-working drill bit ApplicationsPhillips bit Slotted bit Iron-working drill bitCharging Method Removal and Installation Method of BatteryInsert the plug of battery charger into the receptacle Insert the battery to the battery chargerEB 9B ChargingRemove the battery from the battery charger Disconnect battery charger from the receptacleMounting and dismounting the bit Check the attachment of the batteryBefore USE OperationSwitch operation Check the direction of rotationTo use for drilling metal Maintenance and Inspection Service and RepairsStorage Page 10TLRD-N Page Page Please contact Hitachi Koki U.S.A Service Center regarding Collec