Honeywell DN 10DY instruction manual Follow these instructions to avoid the risk of injury

Page 8

Table 1

RECOMMENDED MINIMUM AWG SIZE FOR

EXTENSION CORDS FOR BATTERY CHARGERS

AC Input Rating Amperes*

 

 

AWG Size of Cord

 

 

 

 

Equal to or

but less

 

Length of Cord, Feet (Meter)

 

greater than

than

25 (7.5)

50 (15)

100 (30)

150 (45)

0

2

18

18

18

16

2

3

18

18

16

14

3

4

18

18

16

14

*If the input rating of a battery charger is given in watts rather than in amperes, the corresponding ampere rating is to be determined by dividing the wattage rating by the voltage rating-for example:

1250watts

=10 amperes

125 volts

9.Do not operate battery charger with damaged cord or plug-replace them immediately.

10.Do not operate battery charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman.

11.Do not disassemble battery charger; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.

12.To reduce risk of electric shock, unplug charger from receptacle before attempting any maintenance or cleaning. Removing the battery will not reduce this risk.

IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE BATTERY AND BATTERY CHARGER

You must charge the battery before you can use the cordless driver drill. Before using the model UC12Y, UC14YF and UC14YF2 battery charger, be sure to read all instructions and cautionary statements on it, the battery and in this manual.

REMEMBER: < UC12Y >

USE ONLY HITACHI BATTERY TYPE EB7, EB9, EB12, EB2, B-2, B-3 OR B-4.

OTHER TYPES OF BATTERIES MAY BURST AND CAUSE INJURY! < UC14YF / UC14YF2 >

USE ONLY HITACHI BATTERY TYPES EB7 SERIES, EB9 SERIES, EB12 SERIES, EB14 SERIES. OTHER TYPES OF BATTERIES MAY BURST AND CAUSE INJURY!

Follow these instructions to avoid the risk of injury:

WARNING: Improper use of the battery or battery charger can lead to serious injury. To avoid these injuries:

8

Image 8
Contents Safety Instructions For Cordless Angle Drill Contents Meanings of Signal Words Important InformationSafety Keep Children Away Handle Tool Correctly Important Safety Instructions for Battery Charger Follow these instructions to avoid the risk of injury Disposal of the Exhausted Battery Battery EB9, EB9B ModelName of Parts Cordless Angel Drill DN10DYCordless Angle Drill DN10DY SpecificationsBattery Charger Accessories Standard AccessoriesApplications Phillips bit Slotted bitIron-working drill bit Wood-working drill bitRemoval and Installation Method of Battery Insert the plug of battery charger into the receptacleInsert the battery to the battery charger Charging MethodCharging EB 9BDisconnect battery charger from the receptacle Remove the battery from the battery chargerCheck the attachment of the battery Before USEOperation Mounting and dismounting the bitTo use for drilling metal Switch operationCheck the direction of rotation Storage Maintenance and InspectionService and Repairs Page 10TLRD-N Page Page Service Center regarding Collec Please contact Hitachi Koki U.S.A

DN 10DY specifications

The Honeywell DN 10DY is a state-of-the-art device designed to enhance automation and control in various industrial environments. Known for its robust features and advanced technology, this device is particularly renowned in sectors that require precision and reliability.

One of the primary features of the DN 10DY is its high-performance data logging capabilities. This function enables users to monitor and record critical processes in real-time, ensuring that all necessary data is captured for analysis and reporting. It supports a wide range of data formats, allowing for seamless integration with existing systems.

In terms of communication technologies, the DN 10DY boasts multiple connectivity options, including Ethernet, MODBUS, and RS-232/RS-485 protocols. This versatility allows for easy integration into various types of networks, making it an adaptable choice for both new installations and upgrades of existing systems. The device also supports wireless communication options, ensuring flexibility in data transmission over various distances without the constraints of traditional cabling.

The DN 10DY utilizes advanced sensor technology to provide accurate and reliable measurements. Its sensors are designed to withstand harsh industrial conditions, such as extreme temperatures and humidity levels. This ensures that the device maintains optimal performance and longevity, even in challenging environments.

One of the standout characteristics of the Honeywell DN 10DY is its user-friendly interface. The device features a clear display that simplifies navigation and setup. Users can easily configure settings and monitor performance without extensive training, positioning the device as an excellent choice for operators at various experience levels.

Safety and compliance are paramount in industrial applications, and the DN 10DY meets various international standards, ensuring that users can rely on it for safe operations. Its built-in fail-safes and redundancy measures provide added security and peace of mind, reducing the risk of operational downtime due to equipment failures.

Overall, the Honeywell DN 10DY is a powerful tool for enhancing industrial automation and control. With its comprehensive features, robust communication technologies, and user-friendly design, it stands out as a reliable choice for businesses seeking to optimize their processes and improve operational efficiency.