This section provides the operational procedures for the L-828 style constant current regulators (CCRs) listed below.

Local control procedures

Remote control procedures

Shutdown procedures

WARNING: When installing and servicing the L-828 CCR, do not rely on circuit breaker CB1for safety. When CB1 is turned off, the line voltage is still present on the input terminals and on the CB1 terminals. Always remove power to the regulator using the external circuit breaker or disconnect the switch before installing or servicing the regulator.

This subsection describes local control operations.

See Figure 2-4 in the Description section. Refer to Tables 4-1 and 4-2. The rotary switch for the 3-step CCR has five positions; the rotary switch for the 5-step has seven positions. The rotary switch S1 (6) on the front panel is used for local control of the regulator.

Table 4-1 Rotary Switch S1 Position for 3-Step CCRs

If you set switch S1

The result is...

to the following...

 

REM

Operation of CCR by remote control signals.

OFF

CCR off. Cannot turn on by remote control.

10

4.8 A current output.

30

5.5 A current output.

100

6.6 A current output.

2002 Siemens Airfield Solutions, Incorporated

96A0104B

Page 4-1

All rights reserved

Issued 6/02

 

Image 36
Contents Constant Current Regulators LC-Type 5, and 10 kW/6.6 A/60 Hz Record of Changes Rev Description EC No Checked Approved DateTable of Contents CCRs LC-Type 4, 7.5, and 10 kW/6.6 A/60 Hz Table of Contents List of Figures List of Tables L-828 CCRWarranties Disclaimers Safety Introduction Safety SymbolsSafety Symbols contd Qualified Personnel Intended Use Installation Installation contd Operation CCRs LC-Type 4, 7.5, and 10 kW/6.6 A/60 Hz Safety Description Introduction4, 7.5, and 10 kW CCRs are designed to Indicators Indicator PurposeCCRs LC-Type 4, 7.5, and 10 kW/6.6 A/60 Hz Description Contactor TransformersHz LC-Type L-828 CCRs 10 kW/6.6 a Required EquipmentInput Power Breaker Sizing SpecificationsRatings ClassStyle Power Factor Efficiency Reactive Loading Class Style Brightness Nominal Output PowerResistive Loading Class Style Step Nominal Output Allowable RangeTemperature Range Regulation Environmental Operating ConditionsRelative Humidity Altitude4340 W Weight CCR DimensionsLb kg Section Installation Floor MountingRack Mounting Description Quantity Manufacturer Part NumberWiring Connections and Startup Rack Mounting contdWiring Connections Startup contd Remote Control Wiring 3-Step Wiring Connections Startup contd Remote on-command voltage Terminal Block TB2 Label FunctionIf you use 3-Step CCR Remote Intensity Connect CCI to… Step… If you use 5-Step CCR Remote IntensityWiring Connections TP9Wiring Connections Startup contd Calibrating Regulator Setting Up Regulator for Calibration Adjusting Output CurrentAdjusting Output Current contd Adjusting OvercurrentCCR S1 Position Ammeter Reading Potentiometer Adjusting Overcurrent contd If you set switch S1 Result is To the following OperationIntroduction Local Control Local Control Procedures Remote Control Shutdown ProcedureThen Maintenance Maintenance Schedule Interval Maintenance Task ActionShort-Circuit Test Open-Circuit Test Open-Circuit Test contd Troubleshooting Preliminary Troubleshooting Circuit Breaker/Fuses Description FunctionGeneral Troubleshooting Procedures General Troubleshooting Procedures contd Problem Possible Cause Corrective Action Regulator shuts VA-Indicator redDown from open Circuit protectionProblem Possible Cause Corrective Action VA-Indicator red LED light lit contdIntroduction Using the Illustrated Parts List PartsPart Number Description Quantity 828 CCR 4-10 kW/6.6 a Part Ordering Code Input Voltage828 CCR General Assembly 4-10 kW/6.6 a Parts List 828 CCR General Assembly 4-10 kW/6.6 a Parts List contd LC-Type L-828 CCR Component Parts 1LC-Type L-828 CCR Component Parts 2 LC-Type L-828 CCR Component Parts 3 LC-Type L-828 CCR Component Parts 4of Assembly 4-10 kW/6.6 a Parts List contd828 CCR General CCR See -2. Refer below for the part numbers for the 7.5 kW See -2. Refer below for the part numbers for the 10 kW 828 CCR General Recommended Spare Parts KW/480 VacKW/208-240 Vac Part Number Description10 kW/208-240 Vac 10 kW/480 VacSection Wiring Schematics LC-Type L-828 CCR Internal Wiring Schematic Part 1 LC-Type L-828 CCR Internal Wiring Schematic Part 2

L-828 specifications

The Siemens L-828 is a state-of-the-art aircraft communication and navigation system that is designed to enhance efficiency and safety in aviation operations. This system is equipped with a range of advanced features that cater to the evolving needs of modern air traffic management and avionics.

One of the standout characteristics of the L-828 is its versatile communication capabilities. It incorporates VHF and UHF radio systems, enabling flexible and reliable communication between pilots, air traffic controllers, and other aircraft. The system supports both voice communication and data link services, ensuring that critical information is exchanged seamlessly during flight operations.

In terms of navigation, the Siemens L-828 is equipped with cutting-edge Global Navigation Satellite System (GNSS) technology. This allows for precise positioning and navigation, essential for modern pilotage in complex airspace environments. With built-in performance monitoring, the system can also provide predictive analytics, which enhances situational awareness for pilots and ground controllers.

The architecture of the L-828 is designed for ease of integration with existing aircraft systems. Its modular design allows for straightforward upgrades and the incorporation of additional functionalities as aviation technology continues to evolve. This adaptability ensures that operators can extend the lifespan of their investment by easily implementing new features without requiring a complete system overhaul.

Another key feature of the Siemens L-828 is its robust cybersecurity measures. In an era where the threat of cyberattacks is growing, the system employs advanced encryption techniques and authentication protocols to safeguard sensitive communications and data. This emphasis on security ensures that both operational integrity and passenger safety are maintained.

Moreover, the Siemens L-828 has user-friendly interfaces that reduce pilot workload and enhance overall flight experience. With intuitive controls and clear displays, pilots can easily access critical information, thereby facilitating smoother and safer flight operations.

In conclusion, the Siemens L-828 represents a significant advancement in aviation communication and navigation technology. Its combination of versatile communication capabilities, advanced navigation systems, modular design, and heightened security protocols makes it a crucial tool for modern aircraft. As the aviation industry continues to evolve, systems like the L-828 will undoubtedly play an indispensable role in optimizing flight operations and ensuring safety in the skies.